beautypg.com

Start up operation – Windsor Saber Compact 22 User Manual

Page 11

background image

English

11

Emergency stop button is unlocked
(when the main cable is inserted):
– the charging process is started
– the battery indicator lamp is yellow and

flashing

Î

Add distilled water one hour before the
end of the charging process; follow the
correct acid level. There are correspon-
ding indicators on the battery.

ƽ

Danger

Danger of caustic material!
Adding water to the battery in its dischar-

ged state can cause the acid to leak.

Use safety glasses while handling batte-

ry acid and follow the safety instructions
to avoid personal injury or damage to
clothes.

Should the acid spray on to the skin or

clothes, rinse immediately with lots of
water.

Warning

Risk of damage!
Use only distilled or desalinated water

(VDE 0510) for filling the battery.

Do not add any substances (so-called

performance improving agents), this will
void the warranty.

Warning

Only use maintenance-free batteries while
replacing batteries in package appliances.

Î

If the emergency stop button is pressed,
turn the key switch to position 0 and re-
lease the emergency stop button by
turning.

Î

Turn the main switch to "1".

Warning!

Risk of damage. Raise the squeegee tool
before reversing.
Note
To put the brush drive out of operation im-
mediately release the control handle.

Warning

Risk of damage. Only use the recommended
detergents. With respect to different deter-
gents the operator bears the increased risk
regarding the operational safety and danger
of accident. Only use detergents that are
free from solvents, hydrochloric acid and hy-
drofluoric acid.
Note
Do not use highly foaming detergents. Ob-
serve the meter mixing notes.

Detergent is added to the fresh water on the
way to the cleaning head with the help of a
dosaging device.

Note
1% detergent gets added via the metering
equipment. The metering can be set bet-
ween 0 and 3%. For higher metering, you
can add the entire quantity of detergent to
the fresh water tank.
The metering equipment has been designed
for 2.5 litre (0.66 gal) detergent bottles.

Warning

Risk of blocking on account of drying deter-
gent. The flow meter of the metering equip-
ment can stick on account of drying
detergent and hamper the functioning of the

Maintenance-free batteries (wet batte-
ries)

Recommended batteries

Order No.

Description

6.654-093.0 75 Ah, maintenance-free, 2

pieces required

6.654-097.0 80 Ah, maintenance-free, 2

pieces required

Start up

Operation

Chemical filling

This manual is related to the following products: