beautypg.com

Installation – Waterford Appliances E65-NG1 User Manual

Page 26

background image

26

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

REDUCTION KIT TO

LOWER BTU RATING

FOR E65-1 GAS STOVE

3) Open the front door. Open the right side

door and there is a cutout in the heat shield
through which can be seen a wing nut
threaded on to a stud attached to the front
door. Loosen this nut by turning it counter-
clockwise.

Natural Gas Conversion Kit 260-920
Contains:
Qty.Part #

Description

1

904-593

Burner Orifice #40
(Natural Gas)

1

908-365

Decal "Converted to
27,000 Btu"

1

908-363

Instruction Sheet

Propane Conversion Kit 260-922
Contains:
Qty.Part #

Description

1

904-390

Burner Orifice #52 (Propane)

1

908-365

Decal "Converted to
29,000 Btu"

1

908-363

Instruction Sheet

1) Shut off the gas supply.

2) Open the valve door and remove the con-

trol panel.

The wing nut that holds the front door is

accessible through the cut-out in the right

side heat shield.

E63/E65 Conversion Decal: 908-175

Burner Orifice

9) Unscrew the pilot orifice with the allen key

and replace with the LP pilot orifice in the kit.

INSTALLATION

6) Remove and discard the 3 pressure regu-

lator mounting screws (A), pressure reg-
ulator tower (B) and diaphragm (C).

7) Insure that the rubber gasket (D) is properly

positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.

8) Pull off the pilot cap to expose the pilot

orifice.

10) Remove burner orifice with a 1/2" wrench

and discard. Use a wrench to hold on to the
elbow behind the orifice.

11) Reinstall new burner orifice LP stamped

#50 and tighten.

12) Reverse steps 4) to 2).

13) Attach the Conversion label "This unit has

been converted to Propane" on top of the
Serial # decal. E63/E65: Part #175

14) Replace yellow "Natural Gas" label with red

"Propane" label

15) Check for gas leaks.

16) Check inlet and outlet pressures.

17) Check operation of flame control.

18) Check for proper flame appearance and

glow on logs.

T

HIS CONVERSION MUST

BE DONE BY A

QUALIFIED GAS FITTER IF

IN DOUBT DO NOT DO

THIS CONVERSION !!

This manual is related to the following products: