Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) INSTALLATION

Review the following sequence of instructions
which are typical of most installations. The
sequence may vary depending on wall thick-
ness. Refer to pages 10 to 14 for vent
location and clearance dimensions. If a
Vent Restrictor is required it must be
installed BEFORE any venting is attached
to the stove.

1) Set the unit in its desired location. Check to

determine if wall studs will be in the way of
the venting system, adjust location until all
clearances are met and there are no ob-
structions.

Note: A 1-1/2"(38mm) clearance around

the outer pipe must be maintained
except that only a 1" (25mm) clear-
ance is needed at the termination
end.

INSTALLATION

IMPORTANT:
Do not locate termination hood
where excessive snow or ice build-
up may occur. Be sure to check
vent termination area after snow
falls, and clear to prevent acciden-
tal blockage of venting system.
When using snow blowers, make
sure snow is not directed towards
vent termination area.

2) Assemble a trial fit to determine the ver-

tical center-line for the vent termination.

a) Cut a 9-1/2" x 9-1/2" (241mm x 241 mm)

square hole on both the interior and
exterior wall.

secure with 3 of the #8 x 1/2" screws
(stainless steel).

4) Attach the adjustable pipe section to the

vent terminal using Mill-Pac and/or high
temperature silicone and attach with 3 of
the #8 x 1/2" screws (stainless steel).

Hint: Apply the sealant (Mill-Pac and/or high
temperature silicone) to the outer pipe before
connecting the inner pipe.

Note: The pipe

s e a m
should be
f a c i n g
down.

Note: To make the installation more aes-

thetically pleasing, we recom-
mend framing out a square that
the cap can be mounted on.

Note: If installing ter-

mination on a
siding covered
wall, a vinyl sid-
ing standoff or
furring strips
must be used
to ensure that
t h e t e r m i n a -
tion is not re-
cessed into the siding. For vinyl
siding standoff installation refer
to the Dura-Vent Termination in-
structions.

5) Slide the partially connected pipe and vent

terminal assembly through the wall thim-
bles (from the exterior into the interior) and
secure the cap to the exterior wall with 4
of the supplied screws (#8 x 1-1/2" drill

3) Attach the 4" dia. flex liner to the vent

terminal ensuring that the flex overlaps the
collar of the vent terminal by a minimum of
1-3/8"(35mm). Use Mill-Pac to seal and

b) Install wall thimbles on both interior

and exterior wall with 4 wood screws
(#8 x 1") per thimble.

c) Attach the 2 piece adjustable pipe

section to the vent terminal and slide
into position from the exterior. The
larger diameter end of the ad-
justable pipe goes to the vent
terminal.

d) Install the 90

o

elbow onto the adjusta-

ble pipe to determine the vertical
centerline.

Note: if the centerline cannot be
met, the adjustable sections will
have to be cut.

e) Cut the 4 ft. section of rigid pipe to

length. Attach the 45

o

elbow to the

rigid pipe, and ensure that the pipe
length when cut (with the 45

o

elbow)

will seat onto both the starter collar
and the 90

o

elbow. Crimped sec-

tion of rigid pipe seats into the 90

o

elbow. Only cut the uncrimped
side of pipe.

Dismantle all pipe sections including vent
terminal.