beautypg.com

Installation, Aeration adjustment, High elevation – Waterford Appliances E65-NG1 User Manual

Page 24: Gas connection

background image

24

Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

AERATION

ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply, air
supply or altitude.

HIGH ELEVATION

This unit (with 38,000 Btu) is approved in Can-
ada for altitude 2000 ft. to 4500 ft. (CAN/CGA-
2.17-M91) with the orifice kit Part # 621-975. For
Natural Gas installations above 4500 ft. follow
current CAN/CGA-B149.1. In U.S.A., for installa-
tions above 2000 ft. refer to current ANSI Z223.1
Sc8-8.1.2a appendix F, for resizing orifice.

INSTALLATION

The aeration adjustment gears are located on
the right side of the
burner box and can
be accessed from
the side.

To adjust the aera-
tion: use the allen
key to turn the turn-
ing gear which will adjust the air shutter. Open
the air shutter for a blue flame or close it for a
yellower flame. The factory setting should be
sufficient for most installations.

Note: Prior to any pressure testing of

the gas supply piping system that
exceeds test pressures of 1/2
psig, this appliance must be dis-
connected from the piping sys-
tem. If test pressures equal to or
less than 1/2 psig are used then
this appliance must be isolated
from the piping system by closing
its individual manual shut-off valve
during the testing.

Caution: Carbon will be produced if the
air shutter is closed too much.

Note: Any damage due to carboning re-

sulting from improperly setting
the aeration controls is NOT cov-
ered under warranty.

Note: Aeration Adjustment should only

be performed by an authorized
Regency Installer at the time of
installation or service.

GAS CONNECTION

The gas connection is a 3/8" NPT 90

o

elbow.

The gas line can be rigid pipe or to make
installation easier, use a listed flexible connec-
tor and/or copper tubing if allowed by local
codes. Since some municipalities have addi-
tional local codes it is always best to consult
with your local authorities and the CAN/CGA
B149 installation codes.

For USA installations follow local codes and/
or the current National Fuel Gas Code, ANSI
Z223.1.

When using copper or flex connectors use
only approved fittings. Always provide a union
so that gas lines can be easily disconnected
for burner and/or valve servicing. Flare nuts
for copper lines and flex connectors are usu-
ally considered to meet this requirement.

IMPORTANT: ALWAYS CHECK FOR
GAS LEAKS WITH A SOAP AND
WATER SOLUTION OR GAS LEAK
DETECTOR. DO NOT USE OPEN
FLAME FOR LEAK TESTING.

Clockwise to open,

counter-clockwise to close.

SYSTEM DATA - E65-1

(WITH 38,000 BTU)

For 0 to 2000* feet altitude
Burner Inlet Orifice Sizes:

Natural Gas

Propane

Burner #32

#50

*Above 2000 ft. see National Fuel Code
Orifice Chart.

Max. Input Rating

- Natural Gas

38,000 Btu/h

- Propane

38,000 Btu/h

Min. Input Rating

- Natural Gas

19,000 Btu/h

- Propane

19,000 Btu/h

Output Capacity with blower Off*

Natural Gas

29,070 Btu/h

Propane

29,650 Btu/h

Output Capacity with blower On *

Natural Gas

29,564 Btu/h

Propane

30,172 Btu/h

*See page 8 for manufactured home chart.

Supply Pressure

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

Manifold Pressure

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

SYSTEM DATA

HIGH ELEVATION: E65-NG1

For 2,000 - 4,500 feet altitude
Burner Inlet Orifice Sizes:

Natural Gas
Burner

#33

Max. Input Rating

- Natural Gas

36,100 Btu/h

Min. Input Rating

- Natural Gas

18,000 Btu/h

Output Capacity with blower Off

Natural Gas

27,616 Btu/h

Max. Output Capacity with blower On

Natural Gas

28,086 Btu/h

SYSTEM DATA -

E65-1 CONVERTED TO

27,000 (NATURAL GAS)

OR 29,000 (PROPANE)

For 0 to 4500 feet altitude
Burner Inlet Orifice Sizes:

Natural Gas Propane
Burner #40

#52

Max. Input Rating

- Natural Gas

27,000 Btu/h

- Propane

29,000 Btu/h

Min. Input Rating

- Natural Gas

13,500 Btu/h

- Propane

14,500 Btu/h

Output Capacity with blower Off*

Natural Gas

19,845 Btu/h

Propane

22,040 Btu/h

Output Capacity with blower On *

Natural Gas

20,385 Btu/h

Propane

22,765 Btu/h

*See page 8 for manufactured home chart.

Supply Pressure

Natural Gas

min.

5.0" w.c.

Propane

min.

12.0" w.c.

Manifold Pressure

Natural Gas

3.8"

+/- 0.2" w.c.

Propane

11"

+/- 0.2" w.c.

with 38,000 Btu with 27,000 (NG) /

29,000 LP

Natural Gas Natural Gas

3/8"(9.5mm)

3/16"(4.75mm)

Propane Propane

wide open

1/4" (6.35mm)

This manual is related to the following products: