Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove

13

INSTALLATION

RIGID PIPE VENTING - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES

The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with
vertical terminations.
Maximum t w o 45

o

elbows, not including the 45

o

elbow attached to the unit. All vertical and offset to vertical

vent installations require Vent Restrictor #1. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

Offset to Vertical Terminations

(Vent Restrictor #1)

Straight Vertical Terminations

(Vent Restrictor #1)

Rigid Pipe Venting - Horizontal Terminations

Only for Units Converted to Lower Btu Rating: 27,000 (NG), 29,000 (LP)

The two diagrams below show all allowable combinations of straight horizontal termination with one 45

o

elbow off the unit.

Dura-Vent Snorkel Termination

Riser Vent Termination