OPTIONAL DOOR

GRILL INSTALLATION

Door Grill Kit Contains:

Qty. Description

1

Front Door Grill

4

Screws

4

Grill Clips

1) Open the front door. Open the right side

door and there is a cutout in the heat shield
through which can be seen a wing nut
threaded on to a stud attached to the front
door. Loosen this nut by turning it counter-
clockwise.

5) Distribute the embers along the front burner

but do not cover the burner ports and
around the logs. Place the embers on the
floor of the firebox. Place the lava on the
burner tray in front of the left and right front
logs. See Diagram 4.

Diagram 4

Diagram 3

Diagram 1

Note: Do not force logs down.

Diagram 2

3) Place the left front log, carefully sliding it

down onto the left pins of the front burner.
See diagram 2.

LOG INSTALLATION

WARNING: Dangerous operating condi-
tions may occur if these logs are not
positioned in their approved locations.
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
and burner operation.

a)

Front Right Log - Part # 902-020

b)

Front Left Log - Part # 902-021

c)

Rear log - Part # 902-022

d)

Embers - Part # 902-151 (1 bag)

e )

Lava - Part # 902-154 (1 bag)

(Part # 560-935 for the set of three logs)

1) Remove the logs from the box and carefully

unwrap them. The logs are fragile, handle
with care - DO NOT FORCE into position.

2) Place the rear log, carefully sliding it down

onto the pins, with the flat side of the log
facing the back of the unit. See diagram 1.

4) Carefully remove the logs, embers and rock-

wool.

5) Remove burner.

Burner Orifice

INSTALLATION

Note: Use a
magnetic type
screwdriver if
possible.

6) Remove burner orifice with a 1/2" wrench

and discard.

7) Reinstall new burner orifice (NG stamped

#40 or LP stamped #52) and tighten.

8) Reverse steps 5) to 2).

9) Attach the label "This unit has been con-

verted to..." on top of the Serial # decal over
the higher Btu information.

10) Check for gas leaks.

11) Check inlet and outlet pressures.

12) Check operation of flame control. Check for

proper flame appearance and glow on logs.

4) Place the right front log, carefully sliding it

down onto the right pins of the front burner.
See diagram 3.