Installation, Vertical termination with co-linear flex system – Waterford Appliances E65-NG1 User Manual
Page 14
14
Waterford E65-1 Emerald Direct Vent Freestanding Gas Stove
VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will accommodate.
However, keep the flexible liner as straight as possible , avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION
Required Parts:
Part #
Description
945G
45
o
Elbow
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
270-944
U27 Dura-Vent Adapter
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Alternate Approved Caps
980
Vertical Termination Cap
991
High Wind Cap
923GK 3" Co-linear Adapter with flashing
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
Venting Arrangements - Vertical Terminations
with Co-linear Flex System for both
Residential & Manufactured Homes/
Mobile Homes
The shaded area in the diagram shows the allowable
vertical terminations. If the vent is ENCLOSED in a chase (min.
size 9" x 9") maintain a 1-1/4" clearance to combustibles.
Straight Vertical Terminations