3 repeater information, Figure 4-9 repeater configuration, Table 4-3 general parameters – Viking 242-2009-632 User Manual
Page 50
LTR-Net PROGRAMMER
4-4
March 1999
Part No. 001-2009-600
4.3.3 REPEATER INFORMATION
This menu selection has an equivalent icon in the toolbar. This menu selection or icon brings up the
parameter pages for the selected repeater. It allows entry of information specific to this repeater.
Figure 4-9 REPEATER CONFIGURATION
Table 4-3 GENERAL PARAMETERS
Repeater Number
1-20
Repeater number was established in Locality Configuration.
Channel Number
1-399
Channel number was established in Locality Configuration.
Receive Frequency
Frequency was determined by channel number in Locality Configuration.
Transmit Frequency
Frequency was determined by channel number in Locality Configuration.
Test Mode ID
1-239
Group ID transmitted when the Repeater is in the Test Mode.
Local Mic ID
1-239
Group ID transmitted when the local microphone PTT is active.
Status Free
0=never
20=always
When the number of free channels falls below this value, Status Channel can be
used for voice.
RNT Link
None
FSK
Dig
BnB
Data Signaling type for 3000 Series Switch.
Frequency Shift Keying
RS-232
Blank and Burst (FSK)
RF Power Level
Low, High
Low=25-75, High=75-160. Power level in watts for transmit power output.
Options
Stand Alone
Selected if the repeater is permitted to operate without a connection to the 3000
Series Switch.
High Stability Synth Selected if the Receiver and Transmitter use the High Stability Synthesizer.
Allow LTR
Selected if standard LTR protocol is allowed.
Status Channel
One repeater at a Locality is designated to transmit update information for all
calls occurring at that Locality. Normally not assigned as a Home repeater.
Alarm to CIB
Routes repeater alarms to the Channel Interface Bus to be detected by the Call
Processor and the System and Subscriber Manager.
HSDB All Data
Repeater receives all the data on the High Speed Data Bus.
Xmit Channel Info
Repeater sends updates on all repeaters installed in this Locality.
Power Source
AC, DC
The type of primary power source for the Repeater.
CWID Time
0=disabled, 1-30 min The time interval between CWID transmissions.
CWID Message
Station call letters
This is the FCC station call letters (15 characters/numbers).
OK
Saves the current selections shown and closes the window.
Cancel
Disregards all changes on any of these four screens and closes the window.
Help
Displays the Help screen for the parameters in this window.