beautypg.com

Press f2 to advance to the next screen, Figure 7-17 s100/s101 rs-232, 9 repeater operation – Viking 242-2009-632 User Manual

Page 148: Figure 7-18 new hsdb switch settings

background image

ALIGNMENT AND TEST PROCEDURES

7-20

March 1999
Part No. 001-2009-600

FSK Data Level Adjustment From Repeater
Separate Data Path (4-Wire) Optional Setting.

1. Set MAC S100 Sections 1, 4, 5, 8 OFF; 2, 3, 6, 7

ON; S101 Sections 2, 3, 4 OFF; 1 ON
(see Figure 7-15).

2. Adjust R240 on the MAC to obtain -16 dBm

(123 mV RMS) measured at J100/J103.

3. Press F2 to advance to the next screen.

4. Connect a balanced AC Voltmeter with a 600 ohm

input impedance between balanced lines RXS+ and
RXS- of J2 located on the back of the Repeater (see
Figure 7-14).

5. Adjust R241 on the MAC for the type of line used.

Leased Line/Direct Connect (default)
-12 dBm (194 mV RMS)

Microwave/T1 (optional)
-28 dBm (31 mV RMS)

FSK Data Level Adjustment From Repeater
Data over Voice (2-Wire) Default Setting.

NOTE: This adjustment can only be done after
Voice Audio To Switch is completed.

1. Set MAC S100, all Sections OFF; S101 Sections 2,

3, 4 OFF; 1 ON (see Figure 7-15).

2. Connect a balanced AC Voltmeter with a 600 ohm

input impedance between balanced lines RXA+ and
RXA- of J2 located on the back of the Repeater (see
Figure 7-18).

3. Adjust R240 on the MAC for the type of line used.

Leased Line/Direct Connect (default)
-22 dBm (62 mV RMS)

Microwave/T1 (optional)
-38 dBm (10 mV RMS)

Figure 7-17 S100/S101 RS-232

RS-232 Data To And From Switch (RNT) (Optional)

These are the switch settings only.

1. Set MAC S100, Sections 2, 3, 6, 7 OFF; 1, 4, 5, 8

ON (see Figure 7-17).

2. Set MAC S101, Sections 1, 3, 4 OFF; 2 ON (see

Figure 7-17).

7.6.9 REPEATER OPERATION

New HSDB Test

1. Switch settings on the MPC for RS-485 (new style)

operation are shown in Figure 7-18. S002 all Sec-
tion On. S003 all Section Off.

Figure 7-18 NEW HSDB SWITCH SETTINGS

ON

2

1

8

7

6

5

4

3

ON

2

1

4

3

RX

S-

(G

ND

)

RX

S-

RX

S+

(A

UD

IO

)

RX

S+

(F

SK

)

RX

S-

(G

ND

)

TX

S-

TX

S+

(A

UD

IO

)

TX

S+

(FS

K)

S1

00

S101

FS

K

TX

S+

ON

ON

S3

S2

2

1

8

7

6

5

4

3

2

1

4

3