beautypg.com

Viking 242-2009-632 User Manual

Page 30

background image

INTRODUCTION AND OPERATION

1-14

March 1999
Part No. 001-2009-600

2000 OCXO DRAWER

Size

1.75” high, 17” wide, 14” deep (19” rack mount, 1 rack unit height)

Weight

8 pounds

Shipping Weight

9 pounds

Operational Temperature Range

-30°C to +60°C (-22

°

F to +140

°

F)

AC Voltage/Frequency

115V AC ±15% 50/60 Hz

DC Voltage (w/2 oscillators)

0.2A (115V AC) or 0.1A (230V AC)

DC Voltage (optiona external supply)

15V DC ±15%

DC Current (w/2 oscillators)

< 1A DC at initial turn on
< 0.7A DC after warm-up

Frequency

10 MHz

Reference Signal Outputs

8 - 1.25 MHz outputs

External 10 MHz Signal Input Level

2V P-P minimum (high impendance input)

Output Amplitude

0 dBm ±1 dB (1.25 MHz outputs)
10 dBm ±1 dB (10 MHz output)

Overall Oscillator Output Stability

0.1 PPM

Oscillator Temperature Stability

0.03 PPM (-40°C to +70°C (-40

°

F to +158

°

F)

Oscillator Aging

1 E-9/Day

Oscillator Tuning Range (Mechanical)

Range for 10 years aging adjustable to 0.01 PPM nominal

Single Sideband Noise/Hz

-105 dBc at 10 Hz
-135 dBc at 100 Hz
-150 dBc at 10 kHz

Current handling capability of
alarm relay outputs

2A