beautypg.com

Power cable connector and schematic, 1 ac input requirements, 7 grounding – Viking 242-2009-632 User Manual

Page 33: Caution

background image

INSTALLATION

2-3

March 1999

Part No. 001-2009-600

2.6.1 AC INPUT REQUIREMENTS

AC Input Voltage:

100-240V AC

Line Frequency:

50-60 Hz

AC In-rush:

60A maximum

Overall Efficiency:

>70% at 100V AC
>80% at 240V AC

Lightning protection:

6kV for < 1ms

Power Factor:

>0.97 at full load

Brown Out Voltage:

80V AC

Temperature

-30°C - +60°C (full power)

Power factor correction per IEC555. The Power

supply has the following safety agency approvals
pending: UL1950, CSA22.2-950, TUV EN60950
(IEC950)

When the AC input voltage is below 90V AC, the

maximum output power is decreased to keep the input
current constant. If a battery back-up is installed, the
batteries take over when the AC input voltage falls
below 80V AC (dependent on power output).

The AC input connector is an IEC connector

equipped with a locking mechanism.

The operating temperature range is -30°C to

+60°C (-22°F to +140°F), i.e. the same as the repeater.
The fan is thermostatically controlled by the internal
temperature. When the internal heatsink temperature
reaches +45°C (113°F) the fan turns on. When the
heatsink temperature drops below +35°C (95°F) the
fan turns off. If the internal heatsink temperature
reaches +90°C (+194°F) the power supply turns off
until the heatsink temperature drops below +85°C
(+185°F). The over-temperature shutdown and restart
are automatic.

2.7 GROUNDING

CAUTION

PROPER SITE GROUNDING AND LIGHTNING
PROTECTION ARE VERY IMPORTANT TO PRE-
VENT PERMANENT DAMAGE TO THE REPEATER.

As in any fixed radio installation, measures

should be taken to reduce the possibility of lightning
damage to the Viking VX equipment. Proper ground-
ing eliminates shock hazard, protects against electro-
magnetic interference (EMI) and lightning.

POWER CABLE CONNECTOR AND SCHEMATIC

9

7

12

11

10

8

6

5

4

3

2

1

A

B

C

J2

1

2

3

4

5

6

7

8

9

REPEATER

BACKPLANE

AC FAIL IN

POWER SWITCH

THERMAL SENSOR

+15V

N/C

N/C

-5V

TO

POWER HARNESS

GROUND

+15V

+5V

TO

RFIB

+26.5V

A

B

C

1

2

3

4

5

6

7

8

9

10

11

12

3

6

9

8

5

2

1

4

7

J2

BACKPLANE

N/C