TO DETERMINE
TOTAL STANDBY
LOAD ON BATTERY,
ADD 100mA TO
TOTAL OF AUX.
POWER OUTPUT
AND REMOTE
KEYPAD
CURRENTS.

USE UL LISTED
LIMITED ENERGY
CABLE FOR
CONNECTIONS

CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION SHALL
BE PERMITTED ONLY WITH THE PERMISSION OF THE
LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR
ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE
EMERGENCY NUMBER.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

LOCATED AT

LOWER RIGHT

OF CIRCUIT

BOARD

EARTH

GROUND

SEE

INSTRUCTIONS

FOR PROPER

GROUNDING

TELEPHONE WIRING

(VIA RJ31X* JACK DIRECT

CONNECT CORD)

*in CANADA, CA38A JACK

DOC LOAD NO.: 3

REMOTE KEYPADS

SYSTEM MUST BE
PROGRAMMED WITH A
6139 KEYPAD. IT NEED
NOT REMAIN IN SYSTEM
AFTER PROGRAMMING.
THE SYSTEM CAN USE:
6127 (20mA), 6128 (30mA),
6137 (85mA), 6138 (100mA),
OR 6139 (100mA).

MULTIPLE KEYPADS MAY BE
USED, BUT USE MAX. OF
220 FT. OF #22 WIRE, OR
550 FT. OF #18 WIRE.

BLA

CK:

KEYP

AD GR

OUND (

) RETURN

RED:

KEYP

AD PWR (+)

GREEN:

D

A

T

A

IN FR

OM KEYP

AD

YELLO

W:

D

A

T

A

OUT

T

O

KEYP

AD

REMOTE

KEYPAD(S)

}

SEALED LEAD ACID TYPE
BATTERY. NORMALLY
NEED NOT BE
REPLACED FOR AT
LEAST 3 YRS.

COMPLIES WITH FCC RULES, PART 68

FCC REGISTRATION NO. AC398U-68192-AL-E

RINGER EQUIVALENCE: 0.7B.

THIS EQUIPMENT SHOULD BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION'S STANDARD 72,
CHAPTER 2 (NATIONAL FIRE PROTECTION
ASSOC., BATTERYMARCH PARK, QUINCY,
MA 02269).
PRINTED INFORMATION DESCRIBING PROPER
INSTALLATION, OPERATION, TESTING,
MAINTENANCE, EVACUATION PLANNING AND
REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.

CHARGING

VOLTAGE

13.8VDC

BATTERY

12V, 4AH

+

+

CONNECTOR

TABS

PLUG-IN

TRANSFORMER
16.5VAC, 25VA
(e.g. ADEMCO 1321.
USE 1321CN
in CANDA)

TO 110VAC

UNSWITCHED

OUTLET (24HR)

+

BATTERY FUSE

(e.g. ADEMCO No. 90-12)

FOR REPLACEMENT

USE SAME VALUE

3A

BLK
RED
GRN
YEL

FOR UP TO 16 RF EXPANSION ZONES

1000

OHMS

EOLR

1000

OHMS

EOLR

ZONE 5

ZONE 6

HI

LO

HI

LO

WARNING:

OWNER'S INSTRUCTION NOTICE NOT

TO BE REMOVED. WEEKLY TESTING IS REQUIRED TO
ENSURE PROPER OPERATION OF THIS SYSTEM.

TIP

(BROWN)

RING

(GRAY)

TIP

(GREEN)

RING

(RED)

}

}

INCOMING

PHONE

LINE

HANDSET

BLACK

RED

+

1000

OHMS

EOLR

1000

OHMS

EOLR

ZONE 1

ZONE 2

HI

LO

HI

LO

1000

OHMS

EOLR

1000

OHMS

EOLR

ZONE 3

ZONE 4

HI

LO

HI

LO

• MAXIMUM LOOP RESISTANCE (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-6: 300-500MSEC
• ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR

FAST RESPONSE TO AN OPEN: 10MSEC MAX

• ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE.

ADEMCO 5881* Type

RF RECEIVER

WIRELESS ZONES

5881L: UP TO 8

5881M/5881H/5881EH: UP TO 16

* 5882 Type in CANADA

ADEMCO No. 4204

RELAY MODULE (180mA MAX)

(4 OUTPUT RELAYS)

SET UNIT’S DIP SWITCH

FOR DEVICE ADDRESS OF “0”

(See receiver’s instructions)

SET UNIT’S DIP SWITCH

FOR DEVICE ADDRESS OF “1”

(See unit’s instructions)

THESE OPTIONAL ITEMS

MAY ALSO BE USED

SEE THEIR INSTRUCTIONS

ADEMCO 5800TM

TRANSMITTER MODULE

(20mA)

(for 5827BD Wireless

Bi-directional Keypad)

AND/OR

ADEMCO 4285/4286

VIP MODULE 160mA/300mA

AND/OR

ADEMCO ECP COMPATIBLE

LONG RANGE RADIO

OPTIONAL

24 HR BATTERY STANDBY REQUIRED
FOR FIRE INSTALLATIONS. USE 12V,
17.2AH BATTERY FOR 500 mA AUX
POWER. SEE INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST 4
HOURS.

FOR

COMPLETE

INFORMATION,

SEE

INSTRUCTIONS

N7227V5

RED
JUMPER

CUT FOR BELL SUPERVISION.
ALSO CONNECT A 1000 OHM
EOLR ACROSS SOUNDER

AUX. POWER

OUTPUT

10.5-13.8VDC

500mA MAX.

INTERRUPTS
FOR FIRE
ALARM RESET.
ALL CIRCUITS
ARE POWER
LIMITED.

NOTE:
KEYPAD
CURRENT
MUST BE
INCLUDED
IN AUX.
CURRENT
DRAIN
CALCULA-
TIONS

ALARM OUTPUT

10.5-13.8VDC, 2A MAX.

(600mA MAX. FOR UL USAGE,

INCLUDING AUX. POWER)

STEADY FOR BURGLARY/PANIC, TEMPORAL

SOUNDING FOR FIRE (e.g. USE ADEMCO 740

SOUNDER, 702 OR 719 SIREN, OR 12V BELL)

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.

+

1000

OHMS

EOLR

HEAT

DETECTOR

RED

EOL
POWER
SUPERVISION
RELAY MODULE
A77-716B

VIOLET

AUX PWR

OUTPUT

TERMINALS

5

4

_

+

_

BLK

_

+

V10SE-032-V0

WARNING:

TO PREVENT RISK OF SHOCK, DISCONNECT
TELEPHONE LINE AT TELCO JACK BEFORE
SERVICING THIS UNIT.

Figure 1

7

. V
ISTA

10SE SU

M

M

A

RY

O
F

CO

NNECTIO

NS D

IAGRAM

This manual is related to the following products: