beautypg.com

Vista Ademco N7227V5 User Manual

Page 72

background image

VISTA-10SE Installation and Setup Guide

16–4

02 Start:

Zn List

No List

0

If a zone list will be used to START the relay action, enter the zone list
number (to be programmed in field

81): 1, 2, or 3. If not used, enter 0.

Press the [

] key to continue.

02 Start:

Zn Typ

Not Used

00

If a zone type or system operation will be used to START the relay
action, enter the appropriate two-digit code (see table that follows). If
not, enter 00. Press the [

] key to continue.

CHOICES FOR ZONE TYPES

00 = Not Used

05 = Trouble Day/Alarm Night 08 = 24-Hr Aux

01 = Entry/Exit

06 = 24-Hr Silent

09 = Fire

03 = Perimeter

07 = 24-Hr Audible

10 = Interior w/Delay

04 = Interior Follower

CHOICES FOR SYSTEM OPERATION

20 = Arming–STAY

33 = Any Burglary Alarm

39 = Any Fire Alarm

21 = Arming–AWAY

34 = Code + # + 7 Key Entry

40 = Bypassing

22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry

41 = AC Power Failure

31 = End of Exit Time

36 = At Bell Timeout**

42 = System Low Bat

32 = Start of Entry Time

38 = Chime

58 = Duress

**Or at Disarming, whichever occurs earlier.

02 Stop:

Zn List

No List

0

If a zone list will be used to STOP, or restore, the relay action, enter the
zone list (ZL) number 1, 2, or 3 (to be programmed in

81 mode). If not

used, enter 0.

Press the [

] key to continue.

02 Stop:

Zn Typ

Not Used

00

If a zone type or system operation will be used to STOP the relay action,
enter the appropriate two digit code (see the "ZT" choices listed above). If
not, enter 00. Press the [

] key to continue.

02 A EV ZL ZT

STT 0 0 0 00

This screen again displays a summary of the current relay START
programming.

Press the [

] key to continue.

02 A EV ZL ZT

STP – – 0 00

This screen again displays a summary of the current relay STOP
programming. Press the [

] key to continue.

The display then returns to the first screen so that the next relay number to
be programmed can be entered, unless you enter [0][0] to end relay
programming.

Previously entered data can be reviewed by pressing [#] [8] [0]. After the relay
number is chosen, press [

] to go to the next screens. This is a review mode

only, and data cannot be changed.

This manual is related to the following products: