DYNAMIC SIGNALING DELAY (DSD)

(

1st entry)

This field enables you to select the time the panel should wait for
acknowledgment from the first reporting destination before it attempts
to send a message to the second destination. Delays can be selected
from 0 to 225 seconds, in 15-second increments.

This delay is per message.

0–15 times a 15-second delay. e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Default is “0” (no delay). You must enter “0” for UL installations.

NOTE: If ”0” is entered in this field, the control panel sends
redundant reports to both Primary phone number and LRR.

DYNAMIC SIGNALING PRIORITY (DSP)

(

2nd entry)

This field enables you to select the initial reporting destination for
messages, Primary Phone Number or Long-Range Radio.

0 = Primary Phone Number first; 1 = Long-Range Radio (LRR) first.

Default is “0” (Primary Phone Number)

DOWNLOAD

INFORMATION

(

94,

95)

94

DOWNLOAD PHONE NUMBER

Enter up to 12 digits; 0–9, # +11 for “

”, # + 12 for “#”, # + 13 for a

pause. Do not fill unused spaces. End field by entering

. To clear

entries from field, press

94

.

95

RING DETECTION COUNT FOR DOWNLOADING

Enter number of rings before control picks up phone line (0 to 15).

Refer to the chart below and program this field accordingly.

VIP
Module

Answering
Machine

Downloading

Field

95

Yes

No

No

Set for value other than 0 (1–14). This will
enable the control panel to answer the
phone call. Otherwise, it will not be
possible to access the VIP Module.

Yes

Yes

No

Set for a value higher than the number of
rings for which the answering machine is
set. Example: If machine is set for 4 rings,
use a value of 5 or higher. This is
recommended so that the VIP Module can
still be accessed if the answering machine
is turned off and does not answer the
phone call.

Yes

No

Yes

Set for value other than 0 (1–14).

Yes

Yes

Yes

Enter 15 to bypass answering machine.

No

No

No

Enter 0.

No

No

Yes

Enter 1–14.

No

Yes

Yes

Enter 15. See Important Note below.