VISTA-10SE Installation and Setup Guide

15–2

È

Zone Number

10 Zone Type

Perimeter

03

Zone Type

Ç

Zone Type (ZT): Enter the Zone Type response (or change it, if
necessary).

Each zone must be assigned to a zone type, which defines the way
in which the system responds to faults in that zone.

Enter the Zone Type code (or change it, if necessary). Zone types
are listed below.

NOTE: If you enter 00,

Delete Zone ?

is displayed.

00 = Not used

01 = Entry/Exit #1

02 = Entry/Exit #2

03 = Perimeter

04 = Interior Follower

05 = Trouble Day/Alarm Night

06 = 24-Hr Silent

07 = 24-Hr Audible

08 = 24-Hr Aux

09 = Fire

10 = Interior w/Delay

20 = Arm–STAY

21 = Arm–AWAY

22 = Disarm

23 = No Alarm

Response

Press [

] to continue.

10 Report Code

1st 01 2nd 00

10

Report Code (RC):

Enter the report code. This consists of 2

hexadecimal digits, each in turn consisting of 2 numerical digits.
For example, for a report code of “10,” enter 01 and 00. Refer to the
SYSTEM COMMUNICATION section for more information about
report codes and report code formats.

Press [

] to continue.

Note that report codes are defaulted to 10 for use with CID reporting.

10 INPUT TYPE

RF TRANS 3

Enter Input Device type (In).

Used for Input Type entry.

3 = RF (supervised RF transmitter)

4 = UR (unsupervised RF transmitter)

5 = Button-type RF transmitter (unsupervised)

Transmitter inputs entered as:

“RF” (Supervised RF) Type send periodic check-in
signals, as well as fault, restore, and low-battery signals. The
transmitter must remain within the receiver's range.

“UR” (Unsupervised RF) Type send all the signals that
the “RF” type does, but the control does not supervise the
check-in signals. The transmitter may, therefore, be carried
off-premises.

“BR” (Unsupervised Button RF) Type only send fault
signals. They do not send low-battery, restore, or check-in
signals. The transmitter may be carried off-premises.

NOTE:

For the built-in hardwired zones, the Input Device

type is automatically displayed as HW and cannot be edited.