beautypg.com

Appendix 5, Security – TANDBERG 1000 MXP User Manual

Page 208

background image

D1372202_T1000_MXP_User_Manual

200

Appendix 5

Security


The system has several features both to protect from unauthorized use and system access:

Access Code:


When Access Code is enabled, the user will be asked to enter an access code before he/she is
able to make a call. The system will verify if the entered access code is valid by checking the
code with the allowed codes listed in the access.txt file on the ftp-server in the system. If no
access.txt file is uploaded to the system, registration of the code will be done without validation.
E.g. you can enter whatever code you want and have access to the system.

The access.txt file is a plain text file with one line per access code as shown below:


1234
1250
A1
B2
ABC


To upload this file to the system, follow these steps:

Open a DOS-window and go to the folder where the

access.txt

file is located.

Type ftp

User: press Enter or enter IP-password.

Type

bin

and press Enter.

Go to the user folder, type

cd user

.

Upload the

access.txt

file, type

put access.txt

.

Exit from ftp, type "bye".


Administrator

Password


Access to the administrator menu on the system unit can be controlled using password
protection. You can set the Administrator Password in Menu Settings, in Security or from the
dataport:

menupassword set . The pin-code should be maximum 5 - five digits. To erase the
password, enter an empty pin-code.

Streaming password

By setting a streaming password in the streaming menu on the system, a password has to be
entered on the streaming client to be able to see the video stream from the system.

IP Password