TurboChef Technologies High h Batch User Manual
Page 72
52
Troubleshooting:
“Cook Door Open” Message when Door is Closed
YES
NO
Is wiring from Door Switch to
I/O Control Board OK?
T R O U B L E S H O O T I N G
52
T H E O V E N D O O R
Correct wiring.
If wiring is damaged,
replace the Door
Switch (page 36).
Is the Door Switch
properly installed?
(Ensure it is not loose
or cracked.)
YES
NO
Reset Door Switch.
Replace Door Switch
(page 36).
If problem persists,
ensure Door Actuator
(see Figure 54, below) is
properly installed. If
problem continues to
persist, replace I/O
Control Board
(page 39).
: Door Actuator and Mounting Bracket
Ensure that this side (rather
than the bracket-side) faces
the oven upon reinstallation.
70
N U M B E R
PA R T PA R T
N U M B E R
70
Door Actuator
102789
NOTE: Some oven components have been removed for clarity.