33
T H E C O N T R O L S Y S T E M
Cooling Fans (Figure 40)
Located on the back of the oven, the Cooling Fans
ventilate air into the Electrical Compartment (via the
inlet fan), then back out (via the exhaust fan).
To replace a defective fan:
1. Ensure “Cool Down” process is completed (“Cool
Down” message will disappear upon completion)
and unplug the oven.
2. Remove side panel nearest to defective fan.
3. If removing exhaust fan, remove covering.
4. Remove finger guard.
NOTE: The screws that hold finger guards in place
also hold fans in place.
5. Disconnect Wiring Harness from fan.
6. Install new fan (P/N 100516) and reconnect
Wiring Harness.
7. Reinstall finger guard(s)/covering.
8. Reattach side panel(s).
Airflo
w
5
6
7
8
9
Airflo
w
N U M B E R
PA R T PA R T
N U M B E R
5
Cooling Fans – Inlet/Exhaust
100516
6
Cooling Fan Finger Guard
100087
7
Screw – Cooling Fan Assy (4 x 2 fans = 8)
101694
8
Cover – Cooling Fan (Exhaust)
HHB-8079
9
Screw – Cooling Fan Cover (x3)
101688
: Replacing Cooling Fans