44
T H E C O N T R O L S Y S T E M
Thermostat – Hi-Limit (Figure 49)
The Hi-Limit Thermostat is a 250VAC, 3-Pole,
manual-reset thermostat with a trip point of 572ºF
(300°C). The Thermostat, which interrupts power
to the Heater Element, should never operate during
normal operation.
To replace a defective Hi-Limit Thermostat:
1. Ensure “Cool Down” process is completed (“Cool
Down” message will disappear upon completion)
and unplug the oven.
2. Remove Right Side Panel.
3. Pull back insulation where necessary.
4. Disconnect the Wiring Harness from the
Hi-Limit Thermostat.
5. Replace defective thermostat with P/N 102075.
6. Reconnect Wiring Harness.
7. Reset insulation and reattach Right Side Panel.
N U M B E R
PA R T PA R T
N U M B E R
52
Thermostat – Hi-Limit
102075
53
Screw – Thermostat – Hi-Limit (x2)
101672
54
Screw – Thermostat Clamp
101688
55
Thermostat Clamp
NGC-1152
: Removing the Hi-Limit Thermostat
52
53
54
55
NOTE: Some oven components have been removed for clarity.