Chassis, Panel fastener screw – Transition Networks CPSMC0800-100 User Manual
Page 11
11
CPSMC0800-100 PointSystem
™
Chassis
slide-in-modules
2.2.3
Replacing the Mangement Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precau-
tions when replacing Media Converter Slide-in-Module(s). Failure to observe this
caution could result in damage to, and subsequent failure of, the Management
Module(s).
NOTE: The Managment Modules are NOT hot-swappable.
To replace a Managment Module:
1. Remove the Managment Module to be replaced by loosening the one (1) screw
that secures the Managment Module to the CPSMC0800-100 chassis front.
Slide the Management Module from the CPSMC0800-100 chassis.
2. Align the replacement Mangement Module with the installation slot so that the
panel fastener screw is at the top.
3. Carefully slide the replacement Managment Module into the installation slot.
NOTE: Ensure that the Managment Module is firmly seated against the back of
the chassis.
4. Install the replacement Managment Module by carefully rotating the attached
panel fastener screw clockwise to secure the Managment Module to the
chassis.
Tech Support: 7am-6pm CST (GMT -6:00) 1-800-260-1312 International: 00-1-952-941-7600
PWR
CPSMC-0800
8-Slot Chassis
Mpls, MN 55344
Mpls, MN 55344
Input Power:
Input Power:
110-240 VAC
110-240 VAC
1.6A max. (60W max)
1.6A max. (60W max)
50/60 Hz
50/60 Hz
10BASE-T
INPORT
MCCM10
MGMT
MASTER
OUTPORT
12C
12C-1
TERM
INIT
RX
TX
LNK
PWR
RESET
DB-9
Panel Fastener Screw