Typical maximum cable distance. (Actual distance is dependent upon the
physical characteristics of the network.) (TX) = transmit (RX) = receive
** SBFTF1029-150 and SBFTF1029-151 are intended to be installed in the same
network where one is the local converter and the other is the remote
converter.
*** SBFTF1029-152 and SBFTF1029-153
are intended to be installed in the same
network where one is the local
converter and the other is the remote
converter.
USER’S GUIDE
CBFTF10xx-15x
Slide-in-Module Media Converter
•
Copper to Fiber
•
10/100 Bridging (2-Port)
•
10Base-T/100Base-TX to 100Base-FX
The CBFTF10xx-15x 2-port Ethernet/Fast Ethernet
bridging Media Converter is designed to be
installed in a Transition Networks PointSystem™
chassis and connects 10Base-T Ethernet or
100Base-TX Fast Ethernet twisted-pair copper
network devices to network devices on a 100Base-
FX Fast Ethernet fiber network.
CBFTF1029-150**
RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX)
singlemode, 20 km (12.4 miles)*
CBFTF1029-151**
RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX)
singlemode, 20 km (12.4 miles)*
CBFTF1029-152*** RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX)
singlemode, 40 km (24.8 miles)*
CBFTF1029-153***
RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX)
singlemode, 40 km (24.8 miles)*
Part Number
Port One - Copper
10Base-T/100Base-TX
Port Two - Duplex Fiber-Optic
100Base-FX
CBFTF1011-150
RJ-45
100 m (328 ft)*
ST, 1300 nm multimode
2 km (1.2 miles)*
CBFTF1013-150
RJ-45
100 m (328 ft)*
SC, 1300 nm multimode
2 km (1.2 miles)*
CBFTF1014-150
RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode
20 km (12.4 miles)*
CBFTF1015-150
RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode
40 km (24.8 miles)*
CBFTF1018-150
RJ-45
100 m (328 ft)*
MT-RJ, 1300 nm multimode
2 km (1.2 miles)*
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .5
Cable Specifications . . . . . . . . . . .8
Technical Specifications . . . . . . . .9
Fault Isolation and Correction . .10