TANDBERG GW
Data port Command Interface User Guide
8
• User Commands, Xcom.
Parameter Configuration Commands are commands that set a system parameter to a specific
value. E.g.: The command Xconf telnet mode: "on" enables telnet access on the gateway. If
the command is syntactically correct the GW returns OK, otherwise the GW returns
ERROR. When the parameter is successfully changed, the GW will return the command with
the new value. An example is shown below (the user input is shown in bold).
Xconf telnet mode: "on"
OK
*c xConfiguration Telnet Mode: On
When issuing a Parameter Setting Command without a parameter, the GW will return the
command with the current setting. E.g.:
Xconf telnet mode
*c xConfiguration Telnet Mode: On
OK
Status Commands are commands that list different sets of system parameters. Status
commands are automatically called when corresponding parameters are being changed.
4.2.
The commands
The commands are divided into five groups: System Configuration Commands, General GW
Commands, System Status Commands, Debug Commands and Special Commands.