2 outputs, Outputs – TANDBERG MXP User Manual
Page 181
Administrator Settings
181
4.5.2 Outputs
Audio out 1 - 3
Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, televisions or
audio amplifiers.
Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on
hybrid. The signal is a mix of audio from both the far end and local end (not from Audio in 5).
Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix
of audio from far end and local end (not from Audio in 6).
Note that audio out 2 or audio out 3 never should be connected to a loudspeaker placed in the
same room as the microphones connected to the system. This will cause “howling” and possible
damage to the speaker system. If an output is Off, no audio will be sent to that output.
Out 1 Mode
If Out 1 Mode is set to Auto, the system will select analog or digital (SPDIF) mode dependent on
the detected Audio Module. If a TANDBERG Digital NAM is detected then SPDIF mode will be
selected, otherwise analog mode will be selected.
Setting the Out 1 Mode to either Analog or SPDIF will override the auto-detected mode.
See
Stereo Settings
for more information.
Audio Module
Select Audio Module according to the type of Audio Module installed if this is not automatically
detected. The Audio Module setting is only available if the audio module of the system is
unidentified.
Level Settings
Adjust the audio output levels according to the parameters of the external audio equipment
connected. These levels should only be adjusted when installing new audio equipment. The
default settings are correct for the TANDBERG Digital Natural Audio module and for most
consumer electronics devices (televisions, VCRs, etc.). The volume keys on the remote control
adjust the level of output 1 (the speaker output). The volume control has no effect on other
outputs.