beautypg.com

8 warnings, Warnings – TANDBERG MXP User Manual

Page 116

background image

TANDBERG Maestro MXP

116

3.13.8 Warnings


Any warnings registered by the system will be displayed in the Warnings menu. Open a warning
in the list to get more information about the warning.


The following warnings may be displayed if detected by the system, depending on system type
and configuration:

ISDN BRI warnings

ƒ ISDN is enabled on BRI line x, but the line is not connected. Please check your network

connection or disable the line. (101)

ƒ There is something wrong with ISDN BRI line x. Please check your network connection.

(102)


IP network quality warnings

ƒ The system is experiencing, equal to or more than 5%, packet loss in the IP network.

This may affect the quality of the call.

ƒ The system is experiencing high jitter, equal to or more than 200 ms, in the IP network.

This may affect the quality of the call.

ƒ The system is dropping IP packets due to latency in the network. This may affect the

quality of the call.


ISDN PRI warnings

ƒ ISDN PRI is configured for this system, but the line is not connected. Please check your

network connection or disable the network. (131)

ƒ There is something wrong with the ISDN PRI line (Blue alarm). Please check your

network connection. (132)

ƒ There is something wrong with the ISDN PRI line (Yellow alarm). Please check your

network connection. (133)

ƒ There is something wrong with the ISDN PRI line (D-Channel not active). Please check

your network connection. (134)


External Network warnings

ƒ External Network is configured for this system, but the line is not connected. Please

check your network connection or disable the network. (161)


Leased E1/T1 warnings

ƒ Leased E1/T1 is configured for this system, but the line is not connected. Please check

your network connection or disable the network. (191)

ƒ There is something wrong with the Leased E1/T1 line (Blue alarm). Please check your

network connection. (192)