Function code list (cont.) – Toshiba ESTIA A09-01P User Manual

Page 25

background image

Quick Reference Guide - Page 25

Function Code List (cont.)

Function Code Number

Function

Hydro

Unit

C

Range Default

Remote

ontroller

Outside temperature T1 °C

29 - -15

~

0 -10

Outside temperature T2 °C

- - 0 0

Outside air temperature T3 °C

2B

0 ~ 15

-

10

Setting temperature A at -20 °C

2C - 20

~

55 40

Setting temperature B at T1°C

2D - 20

~

55 35

Setting temperature C at T2°C

2E

-

20 ~ 55

30

Setting temperature D at T3°C

2F

-

20 ~ 55

25

Setting temperature E at +20°C

30

-

20 ~ 55

20

Ratio of Zone 2 in Zone 1 Auto mode (%)

31

-

0 ~ 100

80

Heating

Auto Curve

Settings

Temperature shift of entire Auto curve (°C)

27

-

-5 ~ 5

0

Function 0 = Valid; 1 = Invalid

3A

-

0 ~ 1

1

Frost Protection

Setting temperature °C

3B

-

8 ~ 20

15

Back up heater downtime. 0=5min; 1=10min;

33

-

0 ~ 3

1

2=15min; 3=20min

Back Up Heater

e. 0=10min; 1=20min;

34

-

0 ~ 3

0

Control

Back up heater uptim
2=30min; 3=40min

Zone Selection: 0=Zones 1 and Zone 2;

58

-

0 ~ 1

0

1=Zone 1 Only
Change Setback temperature °C

3 ~ 20

26

-

5

Start time (hour)

-

0E

0 ~ 23

22

Night Setback

End time (hour)

-

0F

0 ~ 23

06

Room temperature control adjustment. 0=Valid;
1=Invalid

-

02

0 ~ 1

0

Compensation for temperature °C

35

-

1 ~ 5

1

Downtime Zone B (x 5min)

36

-

1 ~ 24

(5 ~

s)

120min

6

Room Temperature

Uptime Zone C (x5min)

37

-

(5 ~

s)

6

Setting

1 ~ 24

120min

2 Way Valve

O

l

2 way valve activation for cooling.

3C

-

0 ~ 1

0

peration Contro

0=activated during cooling;

g

1=not activated during coolin

3 Way valve

Op

ol

3 way valve activation.

ater operation;

n

54

-

0 ~ 1

0

eration Contr

0=activated during hot w
1=not activated during hot water operatio

2 Zone Mixing

V

0C

-

3 ~ 24

6

alve Drive Time

Specified Drive Time for Mixing Valve to 90°
open (x 10 sec)

Boiler & Heat

Pump
hronisa

Sync

tion

heat pump.

3E

-

0 ~ 1

0

Boiler synchronisation with
0=synchronised; 1=not synchronised

Maximum

Ope

of Maximum heat pump operation time in hot

07

-

1 ~ 120

30

ration Time

Hot Water Heat

Pump

water operation priority mode (minutes)

Cooling Operation

Activate cooling mode.

e;

02

-

0 ~ 1

1

0=cooling & heating mod
1=heating mode only