Quick Reference Guide - Page 19

Setting DIP Switches on the Board
in the Hydro Unit

• Detach the front cover and the electric parts box cover of
the Hydro Unit.
• Set the DIP switches on the main board.

Switch mode

SW10

Description

Default setting

Alternate

1

Internal pump P1 operating
mode

Continuous operation

OFF

ON HP synchronized

3

External P2 pump operation

Continuous operation

OFF

ON

Interlocked with the
internal pump
synchronized with P1.

Switch mode

SW11

Description

Default setting

Alternate

1

Internal backup heater
operation

Operate

OFF

ON Not operate

2

Hot water cylinder heater
operation

Operate

OFF

ON Not operate

3

Booster heater operation

Operate

OFF

ON Not operate

Switch mode

SW12

Description

Default setting

Alternate

1

Hot water supply operation

Valid

OFF

ON Invalid

2

Zone 1 operation

Valid

OFF

ON Invalid

3

Zone 2 operation

Invalid

OFF

ON Valid

Switch mode

SW13

Description

Default setting

Alternate

1

Type of motorized 3-way valve

• 2-wire spring return type
• 3-wire SPST type

OFF

ON 3-wire SPDT type

2

Interlocking with boiler

Invalid

OFF

ON Valid

3

Auto restart for power failure

Auto restart

OFF

ON Manual restart

Switch mode

SW02

Description

Default setting

Alternate

4

Room thermostat

Invalid

OFF

ON Valid