background image

Getting Started

Troubleshooting Ethernet Connections

Trango Broadband Wireless — TrangoLINK-45

page 15

Troubleshooting Ethernet Connections

If you cannot telnet into the radio or open an HTTP browser session, check your cable connections to ensure proper use
of cross-over vs. straight-through cable, and ensure your PC’s subnet is routable to the radio’s IP address.

System Information (sysinfo) Page

To display system configuration and status information type the command sysinfo.

The sysinfo screen is divided into 7 sections (0 –7)

Section

Description

0

Hardware/Firmware versions & system uptime (since reboot)

1

Mac, serial number, and IP configuration information

2

Opmode, RF info, speed, and peer connection status

3

RF channel table

4

Area code information denotes which channels and power limits are available based on region
code of the radio. Area code is set by the factory and can not be altered by the user.

5

ARQ status, encryption, Auto-rate shift, remarks, and LED RSSI function

6

Ethernet TX/RX statistics.