beautypg.com

4 connection – Toshiba IK-HR2D User Manual

Page 8

background image

8

IK-HR2D

DC IN 12V

Lens (option)

DVI cable

(not supplied)

USB cable

(not supplied)

DVI terminal
USB terminal

DVI monitor

(not supplied)

PC

(not supplied)

DC power supply

(option)

Tri-pod adapter

(option)

4 1 Standard Connection

4 CONNECTION

Less than 11 mm

[0.433”]

4 2 Cautions on Connection

When connecting the camera cables, be sure to turn off the CMOS color camera and any other equipment

connected to it.

For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA approved ungrounded

type AC adaptor with the specifications described below.

We suggest using a mega pixel C mount lens. When using other lenses, the best camera

performance may not be obtained.

(For example, low resolution may occur, focus may be lost through the range of a zoom lens, and flare,

ghost may occur.)

Furthermore, in order to avoid damaging the mounting portion of the camera head, use a lens which has

projection dimension from the mounting base of less than 0.433" (11mm.)

Power supply voltage 㸸 12V DC s10%

Current rating

More than 830mA

Ripple voltage

Less than 50mV (p-p)

Connector

HR10A-7P-4S by HIROSE electronics Co. Ltd
Pins 1, 2 㸸 12V
Pins 3, 4 㸸 GND

* This camera’s video output signal will not automatically sense the resolution of the DVI monitor it is

connected to. If a monitor does not support this camera’s output mode, it will not display anything.
Please be sure to switch the output mode of this camera in accordance with the monitor resolution.
Refer to the item “5.3 Switching video signal output” for the operation.

* About DVI standard

There are three types of DVI connectors: DVI-I (Integrated : digital and analog), DVI-D (digital only),
and DVI-A (analog only).
Please use a DVI-D cable (commercially available) to connect this camera.

* To display video with USB, use a computer which installs a USB 2.0 terminal and USB Video Class

Driver.