Select the menu to change the setting by referring to the item “7.1 Using the Menus”.

When the [MENU UP], [MENU DOWN] buttons are pressed, the “䊲” on the screen moves up and down.

Move the “䊲” to the item whose setting you wish to change.

1 SHUTTERElectronic shutter

The electronic shutter has three modes; AUTO, MANUAL, SS(Synchro Scan).
Press the “Page” button to enter the Shutter Page. Use the “Data Up/Down” buttons to select the Shutter
Mode.

AUTO

The exposure time is controlled automatically to obtain the video level set.

MANUAL

It is possible to select the exposure time from eight speed settings; OFF (1/60s:59.94Hz

setting, 1/50s:50Hz setting), 1/100s,1/125s, 1/250s, 1/500s, 1/1000s, 1/2000s, 1/4000s.

SS

Shutter speed can be set by the horizontal scanning time (1H) unit.

7 3 Menus

DATA UP䠯

AUTO ࠉࠉMANUAL ࠉࠉSS

DATA DOWN䠯

Note:

When setting a rapid shutter speed, sensitivity degrades according to the speed.
When a discharging light such as fluorescent lamp, etc. is used for the illumination,
the flicker may be large.

When an object is moving rapidly, the monitor may display the image distorted and/or
blurred. Also, under the discharging light such as fluorescent lamp, etc., horizontal
striped light and dark patterns may be displayed on the screen. Depending on the
timing of flash and/or strobe firing, the contrast may be displayed on the screen. This
is not a malfunction but just a certain character of the rolling shutter system.

When the shutter speed setting is high, the hue may change depending on shooting
conditions or objects.

7 2 Scene File

DATA UP䠯

FILE A ࠉࠉFILE B ࠉࠉFILE C ࠉࠉFILE D ࠉࠉFILE E

DATA DOWN䠯

Five scene files (A, B, C, D, E) are available as user memories for this unit. These are chosen depending
on shooting conditions. By pressing [DATA UP], [DATA DOWN] buttons while [DISP] button is pressed
and the index menu is displayed, the camera operation is changed immediately from the currently
selected scene file to the next. By pressing [DATA UP], [DATA DOWN] buttons while the Index menu is
displayed, the camera operation is changed immediately from the currently selected scene file to the
next.

Note:
Scene file does not contain the data of set "OPTION."