In-line reports, 2 in-line reports, 1 in-line report command executions – Toshiba MA-1595-1 User Manual
Page 229
4. READ AND RESET REPORTS
EO1-11152
4.2 In-Line Reports
4- 2
4.2 In-Line
Reports
WARNING!
When opening the cash drawer, be careful not to let the drawer hit any person.
4.2.1
In-Line Report Command Executions
Before taking in-line reports, please note the following:
1)
In-line Reset Reports (as well as In-line Read Reports) can be taken on the Master Terminal as long as the
Satellite Terminals are in the idle state (“Signed OFF” condition in case of the cashier code entry type). To
check status of all the terminals connected to the in-line, TERMINAL CONDITION CHECK can be operated
(refer to Chapter 2).
2)
When In-line Reports are taken, the power of each Satellite Terminal must be turned ON but the Mode Lock
can be in any positions.
The operation flow for taking In-line Reports is shown on the next page, and the table of In-line Reports is on the
following pages.
The key operation for each In-line Report is the same as the corresponding terminal report available on the
standalone ECR. However, the key operation can be executed only on the Master Terminal while the [RTR] key
is turned on.
Conditions required on terminals for In-line Report takings:
Read/Reset Reports (Daily or GT)
Master Terminal:
Any time outside a sale
Satellite Terminals:
(NOTE below)
Lock Positions Required:
Master Terminal:
Mode Lock: X/RTR Declaration: ON
Mode
Lock:
Z/RTR Declaration: ON
Satellite Terminals:
Any positions
NOTE: Conditions required on the Satellite Terminals for in-line report takings depend on the system features.
• Cashier code entry type with the CVS spec. selected ... Satellite Terminal during a Sign-OFF, Sign-
ON, and sales entries
• Cashier code entry type without the CVS spec. ... Satellite Terminal during a Sign-OFF, and Sign-
ON with no sales entries performed
• Cashier key type with the CVS spec. selected ... Satellite Terminal during idling, and sales entries
• Cashier key type without CVS spec. ... Satellite Terminal during idling
• When the CVS spec. is selected and there is no collected data, “NO-D” will be printed. When the
collected data is not agreed, “NO-A” will be printed.