Sprinkler Assembly

PROBLEM

POSSIBLE CAUSE – CORRECTIVE ACTION

SPRINKLER WON'T ROTATE

(a)

Debris wedged between stator and turbine.
– Remove obstruction.

(b)

Drive assembly defective.
– Replace drive assembly.

(c)

Nozzle base assembly defective.
– Replace nozzle base assembly.

HEAD STICKS UP

(a)

Dirt in riser assembly.

– Flush out. (See Flushing Procedure on page 11.)

(b)

Damaged or missing return spring.
– Replace.

(c)

Damaged riser.
– Replace.

POOR DISTRIBUTION PATTERN

(a)

Nozzle plugged with debris.
– Clean or replace nozzle.

(b)

Nozzle orifice damaged.
– Replace nozzle.

(c)

Low operating pressure.
– Determine why system overloaded and correct.

Main Valve

PROBLEM

POSSIBLE CAUSE – CORRECTIVE ACTION

VALVE WON'T CLOSE

(a)

Continuous 24 VAC to sprinkler.

(Electric )

– Check controller for voltage source.

(b)

Leak in pilot valve assembly.
– Replace pilot valve assembly.

(c)

Plugged supply screen on piston.
– Clean or replace screen.

(d)

Manual control selector on pilot valve assembly turned to "ON" position.
– Turn to "AUTO" position.

(e)

Plunger movement restricted.
– Inspect and clean or replace.

(f)

Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.

(g)

Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.

(h)

Damaged piston seal or piston assembly.
– Replace valve assembly.

VALVE WON'T CLOSE

(a)

Leak in control tubing.

(Hydraulic)

– Isolate and repair.

(b)

Pilot valve leak in controller.
– Confirm by observing constant dripping from discharge line of controller.

Refer to Controller Service Manual.

(c)

Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.

(d)

Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.

(e)

Damaged piston seal or piston assembly.
– Replace valve assembly.

VALVE WON'T OPEN

(a)

Control (field) wires severed.

(Electric)

– Isolate and repair.

(b)

No power to controller.
– Establish controller power.

(c)

No power from controller to solenoid.
– Check for blown fuse and replace.

(d)

Manual control selector on pilot valve assembly turned to "OFF" position.
– Turn to "AUTO" position.

(e)

Pilot valve solenoid inoperative.

– Remove and replace.

(f)

Pilot valve plunger movement restricted.

– Inspect, clean and/or replace.

(g)

No supply from main valve.

– Debris in control tube, main valve assembly and/or communication passages in

body. Flush thoroughly.