NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

NEW YORK CITY, NY AND MASSA-

CHUSETTS REQUIREMENTS

These appliances are approved for instal-

lation in the following USA locations listed

in the following:

Massachusetts -

Installation of these fireplaces are ap-

proved for installation in the US state of

Massachusetts if the following additional

requirements are met -

• Installation and repair must be done by

a plumber or gas fitter licensed in the

Commonwealth of Massachusetts.

• The flexible gas line connector used shall

not exceed 36 inches (92 centimeters)

in length.

• The individual manual shut-off must be

a T-handle type valve.

Massachusetts Horizontal Vent Re-

quirements

In the Commonwealth of Massachusetts,

horizontal terminations installed less than

seven (7) feet above the finished grade

must comply with the following additional

requirements:

• A hard wired carbon monoxide detector

with an alarm and battery back-up must

be installed on the floor level where the

gas fireplace is installed. The carbon

monoxide detector must comply with

NFPA 720, be ANSI/UL 2034 listed and

be IAS certified.

• A metal or plastic identification plate

must be permanently mounted to the

exterior of the building at a minimum

height of eight (8) feet above grade and

be directly in line with the horizontal

termination. The sign must read, in

print size no less than one-half (1/2)

inch in size, “GAS VENT DIRECTLY BE-

LOW. KEEP CLEAR OF ALL OBSTRUC-

TIONS.”

New York City, New York

These fireplaces are approved for instal-

lation in New York City in the US state of

New York.

HI

LO W

HT

PT

HT

PT

PILO

T

PIL

OT

ON

it

OFF

IN

OUT

Manifold Pressure Tap

Inlet Pressure Tap

SIT Millivolt Gas Valve

Pilot Adjustment

Screw

HI/LO Variable

Flame Height

Adjustment

Main Gas

Control Knob

OFF/PILOT/ON

Figure 1

Figure 3

Honeywell Electronic Gas Valve

FF

O

NI

P

S

I

N

O

L

O

RT

N

O

C

GI

N

TIER

Manifold Pressure

Port

ON / OFF Switch

Inlet

Pressure

Port

Electronic Gas

Control Valve

ON

OFF

PIL

OT

LO

H

I

Figure 2

GAS CONTROL

KNOB

CONVERTIBLE

HI/LO REGULATOR

(adjusts flame height

and heat output)

INLET

PRESSURE

TAP

PILOT

ADJUSTMENT

SCREW

WIRING

TERM-

INALS

OUTLET

PRESSURE

TAP

TP/TH

PIEZO

IGNITER

TH

TP

Honeywell Millivolt Gas Valve