beautypg.com

TOA Electronics SSDV-3328 User Manual

Page 2

background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

TABLE OF CONTENTS

Packaging .........................................Page 2
Introduction ......................................Page 2
General Information ..........................Page 2
Requirements for the
Commonwealth of Massachusetts .Page 4
New York City Approval .....................Page 4
Cold Climate Insulation .....................Page 5
Location ............................................Page 5
Manufactured Home Requirements ..Page 6
Vent Termination Clearances ............Page 7
Minimum Clearances to Combustibles ..Page 9
Detailed Installation Steps .................Page 10
Typical Installation Sequence ...........Page 10
Step 1. Framing .................................Page 10
Step 2. Routing Gas Line ..................Page 10
Fireplace Specifications .....................Page 11
Step 3. Install the Venting System ....Page 13
Vertical Termination Systems ............Page 14
Vent Section Length Chart ................Page 14
Vertical Vent Tables and Figures ........Page 17
Horizontal Termination System .........Page 19
Horizontal Vent Tables and Figures ...Page 21
Venting Using Flexible Vent Pipe .......Page 24
Step 4. Field Wiring ...........................Page 25
Step 5. Optional Blower Kit Wiring ....Page 25
Step 6. Connecting Gas Line .............Page 26
Step 7. Checking Unit Operation .......Page 27
Step 8. Installing Logs .....................Page 28
Step 9. Installing Glass Door ............Page 30
Step 10. Burner Adjustments ............Page 31
Step 11. Hood Installation .................Page 31
Finishing Requirements ....................Page 31
Installation Accessories ....................Page 32
Gas Conversion Kits ..........................Page 34

This installation manual will help you obtain

a safe, efficient, dependable installation for

your appliance and vent system.

Please read and understand these

instructions before beginning your

installation.

INTRODUCTION

These vented gas fireplace heaters are sealed

combustion, air circulating gas fireplaces de-

signed for residential applications.

Approved Vent Components - These fireplaces

are designed, tested and listed for operation

and installation with, the following vent com-

ponents only:

Secure Vent™ Direct Vent System Compo-

nents,

Secure Flex™ Flexible Vent Components

manufactured by Security Chimneys Inter-

national and

Z-FLEX™ Model GA Venting Systems listed

to UL1777 and ULCS635 manufactured by

Flexmaster Canada Limited.

These approved vent system components are

labeled for identification. DO NOT use any other

manufacturer’s vent components with these

appliances. Use only the correct size venting

(4-1/2" inner & 7-1/2" outer).

These appliances comply with National Safety

Standards and are tested and listed by OMNI-

Test Laboratories, Inc. (Report No. 116-F-29-5)

to ANSI Z21.88 (in Canada, CSA-2.33), and

CAN/CGA-2.17-M91 in both USA and Canada,

as vented gas fireplace heaters.

PACKAGING

The assembled vented gas fireplace heater is

packaged with:

1 - One log set located in firebox area.

2 - One envelope containing the literature pack-

age which consists of the homeowner's

manual, installation instructions, and war-

ranty; envelope is located in the control

compartment.

3 - One vent restrictor to be applied as shown on

Page 13; restrictor is taped to the envelope.

4 - One hood located behind the top panel.

5 - One bag of decorative volcanic stone located

in the control compartment.

6 - One bag of glowing embers located in the

control compartment.

This appliance is only for use with the type

of gas indicated on the rating plate. This ap-

pliance is not convertible for use with other

gases, unless a certified kit is used.

Cet appareil doit être utilisé uniquement avec

les types de gaz indiqués sur la plaque signalé-

tique. Ne pas l'utiliser avec d'autres gaz sauf si

un kit de conversion certifié est installé.

Misc. Codes / Standards -

Installation must conform to local codes. In the

absence of local codes, installation must comply

with the current National Fuel Gas Code, ANSI

Z223.1. (In Canada, the current CAN-1 B149

installation code).

The appliance, when installed, must be electri-

cally grounded & wired in accordance with local

codes or, in the absence of local codes, with the

National Electrical Code, ANSI / NFPA 70-latest

edition, or the Canadian Electrical Code, CSA

C22.1 - latest edition.

GENERAL INFORMATION

Note: Installation and repair should be per-

formed by a qualified service person. The

appliance should be inspected annually by

a qualified professional service technician.

More frequent inspections and cleanings may

be required due to excessive from carpeting,

bedding material, etc.

S'assurer que le brùleur et le compartiment des

commandes sont propres. Voir les instructions

d'installation et d'utilisation qui accompagnent

l'appareil.

Provide adequate clearances around air open-

ings and adequate accessibility clearance for

service and proper operation. Never obstruct

the front openings of the appliance.

The Millivolt appliances have a millivolt

gas control valve with piezo ignition system

which provides safe, efficient operation. If any

optional accessories that will require electrical

power are to be installed, the electrical power

must be provided at the time of appliance

installation.

The Electronic appliances have an electronic

intermittent pilot ignition system which

provides safe, efficient operation. External

electrical power is required to operate these

appliances.

Both millivolt and electronic versions of

these appliances are listed by OMNI-Test

Laboratories for installation in bedrooms

and Manufactured Homes.

Manufactured Homes -

See Manufactured Home Requirements on

Page 6 for additional information.

WARNING

Improper installation, adjust-

ment, alteration, service or

maintenance can cause injury

or property damage. Refer to

this manual. For assistance or

additional information consult

a qualified installer, service

agency or the gas supplier.