NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

SV4.5 HT-2

Termination

SV4.5 HT-2

Termination

Horizontal terminations have been designed to perform in a wide range of

weather conditions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the

termination where water from eaves and adjoining rooflines may create a heavy

flow of cascading water onto the termination cap. If the cap must be placed

where the possibility of cascading water exists, it is the responsibility of the

builder to direct the water away from the termination cap by using gutters or

other means.

Take care to carefully follow the installation instructions for the termination,

including the use of silicone caulking where required.

Figure 33

Figure 32 -

INSTALLING SQUARE HORIZONTAL TERMINATION (SV4.5HT-2 or SF4.5HT-2)

Siding

Stucco

1-1/4” Maximum Recess of

Square Termination

into Exterior Finishing Material

Exterior Surface of

Framing

Exterior Surface of Siding

Maximum Extent of

Vent Run Sections

Relative to Exterior

Surface of Framing

Interior Surface of

Finished Wall

Last Vent Section.

Use Telescopic Vent

Section (SV4.5LA), If

Necessary

Adapter

SV4.5RCH

Use silicone caulking to seal

the top and sides of the

termination, up to the

underlayment, stucco, or

masonry wall surface.

Caulk

Caulk

Maximum Wall Thickness

10 in. (254 mm)

6 in. to 9-1/4 in.

(152 to 235 mm)

10¹⁄₂"

(267mm)

7"

(178)

5¹⁄₈"

(130 mm)

12¹⁄₈"

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Framed Opening.

6 to 48 inch Vent Section,

Telescopic vent section,

Elbow or Appliance Collar

Base of Appliance

3"

(76 mm)

1"

(25.4 mm)

Adapter

SV4.5RCH

To help minimize water infiltration it is

recommended that the Firestop/Spacer

(SV4.5HF) be installed on the exterior

side of the wall.

Venting Connection and Exterior Wall Recessing of the Horizontal Square

Termination (SV4.5HT-2 or SF4.5HT-2).

See Figure 14 on Page 11 for Min.
Distance to Base of Appliance.

v

For thicknesses greater

than 10", see Table 12

SV4.5 HT-2

Termination

J. Assemble vent run to exterior wall - If not

previously measured, locate the center of the

vent at the exterior wall. Prepare an opening as

described in Step B. Assemble the vent system

to point where the terminus of the last section is

located relative to the exterior surface to which

the termination is to be attached (see Figures

32 & 33 and Table 12 on Page 21.

If the terminus of the last section is not within

this distance, use the telescopic vent section

SV4.5LA, as the last vent section. For wall thick-

nesses greater than that shown in Figure 33 on

Page 20 and Table 12 on Page 21. This table

lists the additional venting components needed

(in addition to the termination and adapter) for

a particular range of wall thicknesses.

K. Attach termination adapter - Attach the

adapter (adapter - SV4.5RCH - provided with the

termination) to the vent section or telescoping

vent section, elbow or appliance collar as shown

in Figures 32 & 33 in the same manner as any

SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall

- When using the square termination, install

SV4.5HF (Secure Vent), SF4.5HF (Secure Flex)

Firestop/Spacer over the opening at the exterior

side of the framing, long side up, with the 3 inch

spacer clearance at the top as shown in Figure

32, and nail into place.

(The Firestop/Spacer may also be installed over

the opening at the interior side of framing).

M. Install the Square Termination (SV4.5HT-2

or SF4.5HT-2)

Install the square termination - For the last step

, from outside the exterior wall, slide the collars

of the termination onto the adapter (the outer

inside the outer and the inner outside the inner)

until the termination seats against the exterior

wall surface to which it will be attached. Orient

the housing of the termination with the arrow

pointed upwards. Secure the termination to

the exterior wall. The horizontal termination

must not be recessed into the exterior wall

or siding by more than the 1-1/4" (32 mm) as

shown in Figure 33.

IMPORTANT

The vent termination is hot while

in operation and for a period of

time following the use of the fire-

place. To prevent contact with hot

surfaces, we recommend the use

of a Termination Guard. See Items

12 and 13 on Page 32. This can be

purchased at your local dealer.