These appliances and their individual shut-off

valves must be disconnected from the gas

supply piping system during any pressure

testing of that system at pressures greater

than 1/2 psig (3.5 kPa).

These appliances must be isolated from the

gas supply piping system (by closing their

individual manual shut-off valve) during any

pressure testing of the gas supply piping

system at test pressures equal to or less than

1/2 psig (3.5 kPa).

Orifice Sizes - Sea Level to High Altitude

(All Models)

These appliances are tested and approved for

installation at elevations of 0-4500 feet (0-1372

meters) above sea level using the standard

burner orifice sizes (marked with an "*" in

Table 6 ). For elevations above 4500 feet,

contact your gas supplier or qualified service

technician . Install the appliance according to

the regulations of the local authorities having

jurisdiction and, in the USA, the National Fuel

Gas Code NFPA 54 / ANSI Z223.1 - latest edition

or, in Canada, the CAN1-B149.1 and .2 codes

- latest edition.

Electronic Models

Electronic models have a fixed rate gas valve.

Input of electronic models is shown in

Table 2.

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate (BTU / HR)

SSDVT/R-3328

17,500

Table 2

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 3

Gas Pressure - All Models

Tables 3, 4 and 5 show the appliances' gas

pressure requirements:

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 4

Test gauge connections are provided on the

front of the millivolt gas control valve, identi-

fied IN for the inlet and OUT for the manifold

side. A 1/8" NPT Test gauge connection

is provided at the inlet and outlet side of

the electronic gas control valve.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

SSDVT/R-3328

#45

*

(0.048")

*

* Standard size installed at factory

Table 6

Manifold Gas Supply Pressure

(electronic models)

Fuel #

Manifold Pressure

Natural Gas

3.5" WC (.87 kPa)

Propane

10.0" WC (2.49 kPa)

Table 5

Input (BTU) Manually-Modulated Gas

Valves (millivolt models)

NATURAL & PROPANE GAS

Models

Input Rate (BTU / HR)

SSDVT/R-3328

17,500 high

13,500 low

Table 1

These appliances are designed to operate on

natural or propane gas only. To operate on

Propane Gas a field converion is necessary

(see Pages 34 to 36). Do not use any other

fuels. The use of other fuels, or combination

of fuels, will degrade the performance of this

system and may be dangerous.

These fireplaces are designed as supplemen-

tal heaters. Therefore, it is advisable to have

an alternate heat source when installed in a

dwelling.

Millivolt Models - The millivolt appliances are

manually controlled and feature a spark igniter

(piezo) that allows the appliance's pilot gas to

be lit without the use of matches or batteries.

This system provides continued service in the

event of a power outage.

Millivolt models come standard with a manu-

ally-modulated gas valve; flame appearance and

heat output can be controlled at the gas valve.

The BTU Input for these appliances is shown

in Table 1.