NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Burner Flame Appearance Models -

SSDV-3328 Series

Figure 55

Main Burner Factory Air Shutter

Opening Setting - Inches (millimeter)

Model

Natural

Gas

Propane

Gas

SSDVT-3328

SSDVR-3328

1/32

(0.826 mm)

5/16

(7.94 mm)

Figure 56

Combustible Finished

Wall Materials

Top of Appliance

Combustible material may

touch the appliance top

Louvers

Top of Door Frame

Hood must be installed as shown.

3"

(76 mm)

This Area Must

Remain Clear of

Combustible

Materials

1 in. Min.

(25 mm)

Drywall Bracket / Spacer

Top Spacers

Figure 57

- Combustible Wall Framing

Burner Air Shutter Adjustment

Adjustment Rod Up

(Fully Open Position)

Air Shutter

Adjustment Rod Down

(minimum air opening

position)

Burner Tube

Adjustment Setscrew

Ref. Air shutter Patent:

U.S. Pat. 5,553,603

Step 11. HOOD INSTALLATION

(Refer to Figure 57)

All of these appliances must have hoods installed prior to operat-

ing.

Slide the hood into the slots on the lower edge of the cabinet top.

FINISHING REQUIREMENTS - Wall Details

Complete finished interior wall. To install the appliance facing flush

with the finished wall, position framework to accommodate the thick-

ness of the finished wall (Figure 57).

See Page 6 for Cold Climate Insulation

and Page 9 for Clearances

Burner Air Shutter Adjustment Procedure

CAUTION

The air shutter door and nearby appliance surfaces are

hot. Exercise caution to avoid injury while adjusting

flame appearance.

Burner Air Shutter Adjustment Procedure

1. Locate adjustment rod and adjust air shutter to the standard setting

as shown in Figure 56 (adjustment rod is located in the lower control

compartment).

Note: Move the adjustment rod down to decreases air and up to

increases.

2. Light appliance (follow lighting procedure on lighting label in control

compartment or see Care and Operations manual).

3. Allow the burner to operate for at least 15 minutes while observing

the flame continuously to ensure that the proper flame appearance

has been achieved (see Figure 55). If the following conditions are

present, adjust accordingly.

• If flame appears weak or sooty, adjust air shutter, incrementally, to a

more open position until the proper flame appearance is achieved.

• If flame stays lowered blue, adjust air shutter, incrementally, to a more

closed position until the proper flame appearance is achieved.

4. Leave the control knob (off/pilot/on) in the ON position and the burner

OFF/ON switch OFF (& remote switches, if applicable).

5. When satisfied that the burner flame appearance is normal, re-install the

lower control compartment door then proceed to finish the installation.