41DVN / DVSN Direct Vent Gas Fireplace

20009999

T203

Air shutter

12/12/03 djt

IMPORTANT: Always check for gas leaks with a
soap and water solution. Do not use open flame for
leak testing.

NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.

Conversion Kits

Change Natural Change Propane

Model

to Propane

to Natural

41DVN

41DVCKP

--

41DVP

--

41DVDSN

20007906

--

41DVDSP

--

Normal and High

Direct Vent Units - Inputs - Orifice Size - Altitude

BTU/Hr

BTU/Hr

Manifold Pressure Orifice 0 - 2000ft. Altitude in USA

Model

Min. Input

Max. Input

@ Max.

Orifice 0-4500ft Altitude in Canada

41DVN

20,000

30,000

3.5”w.c.

#37 DMS

41DVP

19,000

27,000

10.0” w.c.

#53

41DVDSN

--

30,000

3.5” w.c.

#37 DMS

41DVDSP

--

27,000

10.0” w.c.

#53

Air Shutter Settings

Opening

Model

“A”

41DVN

1/4”

41DVP

Fully Open

41DVDSN

1/4”

41DVDSP

Fully Open

“A”