Oven Location and Placement
WARNING: Death, injury and equipment
damage may result from improper positioning.
WARNING: DO NOT stack ovens without
proper installation of stacking brackets. Contact
Customer Service for more information.
WARNING: DO NOT stack ovens more than
three high.
It is the operator's responsibility to ensure the oven
is properly positioned on countertop. TurboChef
will not warrant any damage or injury to ovens that
fall off countertops due to improper placement.
Proper placement of the oven will enhance
long-term operator convenience and satisfactory
performance. Be sure to place the oven in an area
accessible for proper operation and servicing.
The surface on which the oven is placed must be at
least 30” (762 mm) deep and capable of supporting
200 lbs. (90.7 kg) per oven. The manufacturer shall
not assume liability for damage or injury resulting
from the improper installation of this equipment
including temporary or unstable work stations or
countertops.
The oven must be installed level front to back and
side to side. For additional stability, the oven legs
may be bolted to the countertop if desired.
Installation Near Open Heat Source
Figure 6.
When placing a TurboChef oven near an open heat
source, strictly adhere to the following:
- If the oven is being placed near a grill or stove,
a divider must exist between the oven and the
open heat source, with a minimum of 6” (152
mm) between the oven and the divider.
- If the oven is being placed near a fryer, a divider
must exist between the oven and fryer, with a
minimum of 12” (305 mm) between the oven
and the divider.
- The height of the divider must be greater than
or equal to the height of the oven(s) - page 1.
- Verify oven location has a minimum 10” (254
mm) clearance on top and minimum 2” (51
mm) of clearance on each side.
Ventilation Requirements
The HhC2020 should be operated underneath a
ventilation hood, except where local laws or codes
allow for use without a ventilation hood. For more
information or to order a ventilation hood, contact
800.90
TURBO
, +1 214-379-6000, or your local
distributor.
NOTE: In no event shall the manufacturer assume
any liability for damages or injuries resulting from
installations which are not in compliance with local
and national codes, and with the instructions
previously listed.
Grill
Partition
Above Counter Top:
Single Oven = 17.0” (432 mm)
Double Stack = 30.0” (762 mm)
Triple Stack = 43.0” (1092 mm)
6”
(152 mm)
Minimum
12”
(305 mm)
Minimum
Deep Fryer
Counter Top / Table
Partition
Above Counter Top:
Single Oven = 17.0” (432 mm)
Double Stack = 30.0” (762 mm)
Triple Stack = 43.0” (1092 mm)
Figure 6: Installation Near Open Heat Source