beautypg.com

Ip 67 monobloc i/o splitter boxes for fieldbuses, Connections, Advantys – Quantum Instruments Splitter Boxes User Manual

Page 32: Distributed i/o, ftb splitter boxes

background image

32

Connections

0

IP 67 monobloc I/O splitter boxes
for fieldbuses

0

Advantys™

Distributed I/O, FTB splitter boxes

Sensor/actuator connection

Y-connector connection

FTX CY1208

FTX CY1212

CANopen and DeviceNet buses
Supply to splitter box

Bus input/Bus output

Supply input

Supply output

Bus input

Bus output

(1) Supply to splitter box and sensors.
(2) Supply to actuators.

Profibus-DP bus
Supply to splitter box

Bus input/Bus output

Supply input

Supply output

Bus input

Bus output

(1) Supply to splitter box and sensors.
(2) Supply to actuators.

Note: connectors linked to shielding.

M12 female connector

1

4

S1

0 V

24 V

S2

5

2

3

1

1 2 3 4

3
4

1
3

4

M8
female

M8
female

M12 male

1

1 2 3 4 5

2
3
4
5

1
2
3
4
5

M12
female

M12
female

M12 male

24 V

(1)

24 V

(2)

0 V

0 V

4

5

3

2

1

7/8 male connector

0 V

0 V

24 V

(1)

24 V

(2)

2

5

3

4

1

7/8 female connector

0 V

24 V

4

5

CAN-H

3

2

1

CAN-L

M12 male connector

0 V

24 V

4

5

CAN-H

3

2

1

CAN-L

M12 female connector

24 V

(1)

24 V

(2)

0 V

0 V

4

5

3

2

1

7/8 male connector

0 V

0 V

24 V

(1)

24 V

(2)

2

5

3

4

1

7/8 female connector

M12 male connector

0 V

5 V

4

3

1

5

2

Cable B (red)

Cable A (green)

M12 female connector

0 V

5 V

3

4

2

5

1

Cable A (green)

Cable B (red)

Presentation, functions:
pages 14 - 17

Description, configuration:
pages 18 , 21, 24,

Characteristics:
pages 26, 27

References:
pages 28 - 30

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com