Ordering information, Mechatrolink-ii-compatible position control units, Mechatrolink-ii-compatible motion control units – Omron CPU Unit CJ2 User Manual

Page 35: Serial communications units, Ethernet/ip unit

background image

35

MECHATROLINK-II-compatible Position Control Units

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

5 V

24 V

CJ CPU
Bus Units

MECHATROLINK-II-
compatible
Motion Control Units

Control commands executed by MECHATROLINK-II
synchronous communications.
16 axes max.
Direct operation by ladder programming.
Control mode: Position control, speed control,
or torque control

1

0.36

CJ1W-NCF71

UC1, CE

MECHATROLINK-II-compatible Motion Control Units

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

5 V

24 V

CJ CPU
Bus Units

MECHATROLINK-II-
compatible
Motion Control Units

Position, speed, and torque commands by
MECHATROLINK-II
32 axes max. (Physical axes: 30, Virtual axes: 2)
Motion control language

1

0.6

CJ1W-MCH71

UC1, CE

Note: The CJ1W-MCH71 requires the space of three Units (but just one unit number). A maximum of 10 Units can be mounted

on a single CJ-series Rack, up to three CJ1W-MCH71 Motion Control Units plus one other Unit can be mounted per Rack.

Serial Communications Units

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

Communications

Interface

Communications functions

5 V

24 V

CJ CPU
Bus Units

Serial
Communications
Units

1 RS-232C port and
1 RS-422A/485 port

The following functions can be
selected for each port:
Protocol macro
Host Link
NT Links (1:N mode)
Serial Gateway (See note 1.)
No-protocol (See note 2.)
Modbus-RTU Slave (See note 3.)

1

0.38

(See

note 4.)

CJ1W-SCU41-V1

UC1, N, L,
CE

2 RS-232C ports

0.28

(See

note 4.)

CJ1W-SCU21-V1

2 RS-422A/485 ports

0.38

CJ1W-SCU31-V1

Note 1. The Serial Gateway function is enabled only for Serial Communications Units of unit version 1.2 and later.

2. The no-protocol function is enabled only for Serial Communications Units of unit version 1.2 and later (and a CPU Unit of unit version 3.0 or later is also required).

3. The Modbus-STU Slave function is enabled only for Serial Communications Units of unit version 1.3 and later.

4. When an NT-AL001 RS-232C/RS-422A Conversion Unit is used, this value increases by 0.15 A/Unit. When a CJ1W-CIF11 RS-422A Conversion Unit is used, it increases by 0.04 A/Unit.

EtherNet/IP Unit

Unit

classification

Product

name

Specifications

No. of

unit

numbers

allocated

Current

consumption (A)

Model

Standards

Communications

cable

Communications

functions

Max.Units

mountable

per CPU

Unit

5 V

24 V

CJ CPU
Bus Units

EtherNet/IP
Unit

STP (shielded
twisted-pair) cable
of category 5, 5e, or
higher.

Tag data link
message service

8

(See note)

1

0.41

CJ1W-EIP21

UC1, N, L,
CE

Note: Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU

-EIP CPU Unit.