Zn=x — store phone number, Bn — transmit break, Gn — modem-to-modem flow control – Ositech comm Trumpcard Data/Fax Modem User Manual
Page 59: Kn — break control, Result codes, Examples
User’s Guide and Reference
4 - 27
Modem Command Reference
&Zn=x — Store Phone Number
Parameters
n = 0, 1, 2, or 3, x = dial string
Default
none
Stores a 36-digit dial string (x) in the specified entry (n) for later dialling.
(See DSn command.)
\Bn — Transmit Break
Parameters
1 through 9 (If n = 0, the default value is used; if n is
greater than 9, 9 is used.)
Default
3
When this command is entered during a non-error correction connection,
the modem sends a break signal to the remote modem. The length of the
break is 100 times the n parameter value in milliseconds. If this command
is entered during an error-correcting connection, the break will be sent via
the error-correcting protocol giving no indication of length.
Result Codes
NO CARRIER
If not connected
\Gn — Modem-to-Modem Flow Control
Parameters
0 or 1
Default
0
The command applies in non-error correction mode; the modem enables
or disables the generation or recognition of modem-to-modem XON/XOFF
flow control.
Examples
AT\G0
Disables modem-to-modem flow control
AT\G1
Enables modem-to-modem flow control
\Kn — Break Control
Parameters
0 through 5 (If n is greater than 5, 5 is used.)
Default
5
Determines what the modem will do when a BREAK is received from the
communications software or the remote modem. During error correction
mode, the remote modem's BREAK control setting determines how the
local modem will handle the BREAK.