Ln — line type, Mn — communication mode, Pn — dial pulse ratio (disabled for the u.s.) – Ositech comm Trumpcard Data/Fax Modem User Manual
Page 54: Qn — communication mode, Examples
4 - 22
Trumpcard 14400/28800 Modem
Section Four
&Ln — Line Type
Parameters
0 or 1
Default
0
Controls selection of leased line or dial-up line. Although the modem has
only a single line connection, the power level is changed when setting
leased line operation.
Examples
AT&L0
Dial-up line
AT&L1
Leased line
&Mn — Communication Mode
Parameters
0
Default
None
Same as &Q0.
&Pn — Dial Pulse Ratio (disabled for the U.S.)
Parameters
0,1, 2 or 3
Default
0
Selects the ratio of the off hook (make) to an on-hook (break) interval used
when pulse dialling.
Examples
AT&P0
39%/61% make/break ratio @ 10 pps
AT&P1
33%/67% make/break ratio @ 10 pps
AT&P2
33%/67% make/break ratio @ 20 pps
AT&P3
33%/67% make/break ratio @ 20 pps
&Qn — Communication Mode
Parameters
0, 4 through 6
Default
5
The modem supports three basic communication modes: asynchronous,
autosync, and error correction.