4 - 10
Trumpcard 14400/28800 Modem
Section Four
ATF3
Permit V.23 1200/75 bps connections only
ATF4
Permit V.22 1200 bps connections only
ATF5
Permit V.22bis 2400 bps connections only
ATF6
Permit V.22bis or V.32 4800 bps connections only
ATF7
Permit V.32bis or V.32 7200 bps connection only
ATF8
Permit V.32bis or V.32 9600 bps connections only
ATF9
Permit V.32bis 12000 connections only
ATF10
Permit V.32bis 14400 bps connections only
ATF13
Permit V.FC 14400 bps connection only *
ATF14
Permit 16800 bps connections only *
ATF15
Permit 19200 bps connections only *
ATF16
Permit 21600 bps connections only *
ATF17
Permit 24000 bps connections only *
ATF18
Permit 26400 bps connections only *
ATF19
Permit 28800 bps connections only *
* Only applicable to Trumpcard 28800 version
+Ms Select Line Modulation (28800 only)
Parameters
0 through 3, 9 through 11, 64, 69, 74
Default
11
This extended-format command selects the modulation, optionally
enables or disables automode, and optionally specifies the lowest and
highest connection rates using one to four sub-parameters. The
command format is:
+MS=
Sub-parameter Definitions
1.
(automode enabled or the modulation (audomode disabled) to use in
originating or answering a connection. the options are:
w
Modulation
Possible Rates
0
V21
300
1
V22
1200
2
V.22bis
2400 or 1200
3
V.23
1200