User’s Guide and Reference
4 - 5
Modem Command Reference
Command
Title
Default
&Mn
Communication Mode
(&Qn) *
&Pn
Dial Pulse Ratio
0 *
&Qn
Communication Mode
5 *
&Rn
RTS/CTS Option
0 *
&Sn
DSR Option
0 *
&Tn
Test And Diagnostic
4 *
&V
View Configuration and User Profiles
none
&Wn
Store User Profile
none
&Yn
Designate Default User Profile
0 *
&Zn=x
Store Phone Number
none
\Bn
Transmit Break
3
\Gn
Modem-to-Modem Flow Control
0
\Kn
Break Control
5
\Nn
Operation Mode Control
none *
%Cn
Compression Control
1 *
%En
Disable/Enable Line Quality Monitor
0
%L
Report Received Signal Level
none
%Q
Report Line Signal Quality
none
-Kn
MNP Extended Services
1
*Hn
Link Negotiated Speed
0 *
)Mn
Transmit Level Adjust for Cellular
0
Connection
:En
Compromise Equalizer
1
@Mn
Initial Cellular Power Level
0
[n
Event Based Command
None
* Indicates command is saved in Non-Volatile Memory