In the case of an instruction which uses the Broadcast ID (0XFE), regardless of

the Address 0x10 value, the Status Packet will not be returned.

Address 0X11

Alarm LED. When an Error occurs, if the corresponding Bit is set to 1, then the LED

blinks.

This function operates as the logical “OR”ing of all set bits. For example, when the

register is set to 0X05, the LED will blink when a Voltage Error occurs or when an

Overheating Error occurs. Upon returning to a normal condition from an error state, the

LED stops blinking after 2 seconds.

Address 0X12

Alarm Shutdown. When an Error occurs, if the corresponding Bit is set to a 1, then the

Dynamixel will shut down (Torque off).

This function operates as the logical “OR”ing of all set bits. However, unlike the Alarm

LED, after returning to a normal condition, it maintains a torque off status. To remove this

restriction, Torque Enable (Address0X18) is required to be set to 1.

Address 0x14~0x17

Calibration. Data used for compensating for the differences between Robotis products.

Users cannot change this area.

Bit

Function

Bit 7

0

Bit 6

If set to 1, LED blinks when Ins truction Error occurs

Bit 5

If set to 1, LED blinks when Overload Error occurs

Bit 4

If set to 1, LED blinks when Checksum Error occurs

Bit 3

If set to 1, LED blinks when Range Error occurs

Bit 2

If set to 1, LED blinks when Overheating Error occurs

Bit 1

If set to 1, LED blinks when Angle Limit Error occurs

Bit 0

If set to 1, LED blinks when Input Voltage Error occurs

Bit

Function

Bit 7

0

Bit 6

If set to 1, torque off when Ins truction Error occurs

Bit 5

If set to 1, torque off when Overload Error occurs

Bit 4

If set to 1, torque off when Checksum Error occurs

Bit 3

If set to 1, torque off when Range Error occurs

Bit 2

If set to 1, torque off when Overheating Error occurs

Bit 1

If set to 1, torque off when Angle Limit Error occurs

Bit 0

If set to 1, torque off when Input Voltage Error occurs