MAINTENANCE

6) Cut the cable tie that is holds the wires

connected to the control module.

7) Disconnect the 3 connectors from the

control module.

8) Pull out the control module.

NOTE: The control module is held in place
with velcro.

1) Remove the exterior brick panels.

2) Remove the glass door.

3) Loosen the 2 screws that hold the left side

heat shield in place.

4) Lift up and pull out the heat shield slightly

to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).

Control Module

9) Replace the control module

10) Reverse steps to re-install.

CONTROL MODULE REPLACEMENT

5) Unplug the power source.

a. Release the 2 door latches on the left
and right side at the top of the fi rebox.

b.

Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.

Hinge

Door

Latch

Latch Location

Heat
Shield

Bracket

Heat
Shield

c. Place the door on a soft surface to prevent

scratching.