Installation, Wiring diagram, Aeration adjustment – Regency LIBERTY L900-NG User Manual
Page 38: Inst alla tion
Regency
®
L900 Direct Vent Gas Fireplace
38
INST
ALLA
TION
INSTALLATION
WIRING DIAGRAM
A receptacle is provided on the left hand side
of the unit. 120 Volt AC power must be wired to
the receptacle and the control module plugged
in for the unit to operate fully. The front and
rear burners will operate on low, when the unit
is running on battery back-up.
(Do not cut the ground terminal off under
any circumstances.)
AERATION
ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.
In order to adjust the aeration, the logs, grate
and burners will need to be removed to be able
to access the shutters.
Minimum Air Shutter Opening:
NG Front Burner
1/4"
Rear
Burner
1/2"
LP Front
Burner
1/4"
Rear
Burner
3/8"
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.