beautypg.com

Installation, Inst alla tion – Regency LIBERTY L900-NG User Manual

Page 30

background image

Regency

®

L900 Direct Vent Gas Fireplace

30

INST

ALLA

TION

17)

Ensure that the new rubber gasket (supplied
with coil) is properly positioned and install
the new modulating pressure regulator as-
sembly to the valve using the screws sup-
plied with the kit. Tighten screws securely.

18)

Install the enclosed identifi cation label to the
valve body where it can be easily seen.

19) Attach the LP conversion decal near or

on top of the serial no. decal.

20)

Replace yellow "Natural Gas" label with red

"Propane" label.

21)

Re-install the right side panel and all

electrical connections to the valve. (2 grey
wires to modulating coil.)

22)

Remove the left side panel by undoing the

8 screws.

23)

Locate the control box shown below and
remove the J9 jumper using needle nose
pliers.

24)

Re-install the left side panel.

25)

Re-install the rear log support bracket.

26)

Adjust the burner aeration settings to the LP

settings and install the burners.

Front

Burner 1/4"

Rear

Burner 3/8"

27)

Re-install the grate.

28)

Re-install the glass door.

29)

Re-install the right heat shield.

30)

Continue with completing unit installation.

NOTE:

Once the unit has been installed;

Installer Notice:

This instructions must be left

with

the

appliance.

a)

Turn on the gas supply and check for

gas leaks.

b)

Check the inlet and outlet pressures.

c)

Check operation of fl ame control using
the remote control. Refer to FireWizard
operation manual for details.

d)

Check for proper fl ame appearance.

J9 Jumper Location

J9 Jumper