beautypg.com

Installation, Inst alla tion – Regency LIBERTY L900-NG User Manual

Page 31

background image

Regency

®

L900 Direct Vent Gas Fireplace

31

INST

ALLA

TION

LP Conversion Kit Contains:

Qty. Part #

Description

1

910-462

LP Conversion Coil

1

904-573

Cable Tie

1 910-037

LP Pilot Orifi ce

1 904-641

Orifi ce #50 (back)

1 904-241

Orifi ce #56 (front)

1 904-529

Allen Key

1 918-590

LP Conversion Decal

1 908-528

Red Propane Label

1 918-608

Instruction Sheet

1)

Turn control knob to the OFF position and

shut off the gas supply to the valve.

2)

Remove exterior brick panels, if installed.

3)

Remove the glass door.

a. Release the 2 door latches on the left
and right side at the top of the fi rebox.

b. Swing the door out from the top and

release the hinges on the left and right
side of the door by lifting them up.

Latch

c. Place the door on a soft surface to prevent

scratching.

Hinge

Door

Latch Location

Heat
Shield

4)

Loosen the 2 screws that hold the left side

heat shield in place.

5)

Lift up and pull out the heat shield slightly

to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).

Bracket

Heat
Shield

6) Unplug the power source.

7)

Remove the log set, if installed.

8)

Remove interior brick panels, if installed.

9)

Remove the grate by undoing the 2 screws
on the right and left side.

10)

Remove the front burner by removing the

screw.

11)

Remove the back burner by removing the

screw.

12)

Remove the rear log stand by removing

the 4 screws.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

LP Conversion instructions for when unit is ALREADY INSTALLED.

Grate

Front Burner

Front Burner Removed

Back Burner

Rear Log Stand

INSTALLATION