L676E Direct Vent Gas Fireplace

22

INST

ALLA

TION

VENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS

• Vent must be supported at offsets.
• Firestops are required at each fl oor level and

whenever passing through a wall.

• Maintain clearances to combustibles as listed

in the "Clearances" section.

Refer to "Vent Restrictor Position" section for
details on how to change the vent restrictor
to Set 1, Set 2 or Set 3 if required.

Note: Must use optional fl ue adapter when using

Rigid Pipe (Part # 770-994).

INSTALLATION

The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90

o

elbows, with Rigid Pipe

Venting Systems for Propane and Natural Gas.
Two 45

o

elbows equal to one 90

o

elbow. Maximum

of four 45

o

elbows allowed.